background image

IMPORTANT

 

READ THESE INSTRUCTIONS CAREFULLY AND RETAIN FOR FUTURE REFERENCE 

1  Product information 

This commercial escalator cleaning machine is 
designed to clean all types of escalator and travelator 
treads, and is ideally suited for use in airports, 
shopping centres, retail stores, hotels and 
Underground railway stations. 
The machine is intended for indoor use only in dry 
conditions. 
The following instructions contain important 
information about the machine and safety advice for 
the operator. 
Equipment must be operated, serviced and 
maintained in accordance with the manufacturer’s 
instructions. 

If in doubt contact the supplier of your machine. 

1.1  Important Safety Advice

  

When using electrical equipment basic safety 
precautions should be followed including the 
following. 

  Read all instructions carefully before use.

 

  Keep children and unauthorised persons away from 

the machine when in use. 

 

Do not

 leave the machine connected to the 

electricity supply when not in use, always remove 
the plug from the socket-outlet. 

  Switch off the machine before removing the plug. 

  When unplugging pull the plug, not the supply cord. 

  Keep the power supply cord clear of moving parts. 

During operation hazard may occur when running 
the machine over the power supply cord. 

 

Do not

 operate the machine with a damaged 

supply cord or plug, or after the machine 
malfunctions or is damaged in any way. Contact an 
authorised Service Agent for repair or adjustment. 

  The plug of the power supply cord must be 

removed from the socket-outlet before 
commencing cleaning of the machine or 
undertaking maintenance operations. 

  The power supply cord is to be regularly inspected 

for signs of damage. If the power supply cord is 
damaged, it has to be replaced. 

 

Do not

 use where hazardous dust is present.  

 

Do not

 use in an explosive atmosphere. 

 

 

1.2  Guidelines for the operator 

  Operators must be fully trained in the use of the 

machine in accordance with these instructions, able 
to perform user maintenance and the correct 
selection of brushes. 

  Operators should be physically capable to  

manoeuvre, transport and operate the machine. 

  Operators should be able to recognise unusual 

operation of the machine and report any problems. 

  Keep hands and feet well clear of rotating brushes. 

  Wear suitable footwear to avoid slipping.

 

  Wear suitable clothing to keep dry and warm.

 

 

Do not

 smoke when using the machine. 

 

CAUTION 

- This machine is for dry use only and 

should not be used or stored outdoors in wet 
conditions. 

1.3  Transporting the machine

 

CAUTION - THIS MACHINE IS HEAVY  
Do not attempt to lift the machine without 
assistance.

 Incorrect lifting techniques may result in 

personal injury.  
To move the machine around, pull the handle 
backwards to bring the wheels into contact with the 
floor enabling the machine to be moved easily.  

2  Preparing for use 

1. Carefully remove the machine and brushes from 

their respective packaging. 

2. Check machine for transit damage. Do not use 

machine if damaged. 

3. Raise handle to working position. 

2.1  Fitting the brushes 

WARNING - This appliance has been designed for 
use with the brushes specified by the 
manufacturer. The use of other brushes may 
impair safety. 

Always ensure machine is unplugged before fitting or 
removing parts. 

  Release the two locking pins securing the top cover 

and raise the cover to rest against the handle. 

  Disconnect the two hoses from the brush cowl. 

  Tip the cowl forward to reveal the brush spindles 

(Fig.1). 

  Remove the brush retaining clips from the spindle 

ends, and slide the brush on to the spindle engaging 
the narrow slot with the drive nib and refit the 
retaining clips. 

  Close the brush cowl and reconnect the two hoses. 

  Close the top cover and re-engage the locking pins. 

2.2  Electrical connection

 

Before connecting the machine to the power supply, 
check that your supply voltage corresponds with that 
marked on the rating label on the machine. 

UK only 

The supply cord is fitted with a non rewireable plug 
containing a 13 amp fuse. Should the fuse require 
replacement it must only be replaced by a 13 amp 
fuse conforming to BS1362, and the fuse cover must 
be refitted. If the fuse cover is lost the plug 

must not

 

be used until the correct replacement cover is fitted. 

IMPORTANT

 - If the supply cord is damaged, it must 

only be replaced by a special cord available from the 
manufacturer or an authorised service agent. 

WARNING -THIS APPLIANCE MUST BE EARTHED 

We recommend the use of an RCD (Residual Current 
Device) or an ELCB (Earth Leakage Circuit Breaker) 
between the mains socket and the supply cord plug to 
protect against electric shock. 

Summary of Contents for X46

Page 1: ...ator and Travelator cleaner http www truvox com Products Escalators_and_Sweepers Cimex_X46 CAUTION READ THESE INSTRUCTIONS BEFORE USING THE MACHINE 03 7845 0000 Iss 1 07 04http www truvox com Products Escalators_and_Sweepers Cimex_X46 ...

Page 2: ...2 Fig 1 Fig 2 ...

Page 3: ...ring for use 4 2 1 Fitting the brushes 4 2 2 Electrical connection 4 3 Controls 5 4 Operation 5 4 1 Cleaning the escalator 56 4 2 Stain and spot removal 5 4 3 Dust bag replacement 5 5 Storage 5 6 Maintenance 5 7 After sales service 5 8 Technical specification 6 9 Accessories 6 10 Fault diagnosis 7 11 Guarantee 7 12 Declaration of conformity 8 ...

Page 4: ...eport any problems Keep hands and feet well clear of rotating brushes Wear suitable footwear to avoid slipping Wear suitable clothing to keep dry and warm Do not smoke when using the machine CAUTION This machine is for dry use only and should not be used or stored outdoors in wet conditions 1 3 Transporting the machine CAUTION THIS MACHINE IS HEAVY Do not attempt to lift the machine without assist...

Page 5: ...he machine until the bag is released from the vacuum tubes and carefully remove the bag for disposal Insert new bag pushing the rubber seals firmly over the tube ends until the cardboard collar is flat against the machine wall Fig 2 Close the top cover and locking pins The dust bag should be regularly replaced and the hoses checked for blockages If a bag bursts ensure that the filter is removed an...

Page 6: ... a hand held meter For prolonged operation the wearing of ear defenders is recommended 2 Handle vibration does not exceed 2 5 m s when operating on any surface Measurements recorded by an independent test laboratory 9 Accessories Item Qty Part No Application Nylon brush set 2 05 4096 0000 Regular daily maintenance Tynex brush set 2 05 4097 0000 Periodic deep cleaning see note1 Disposable paper bag...

Page 7: ... to the following conditions CONDITIONS 1 Claims made under the terms of the guarantee must be supported by the original invoice bill of sale issued at the time of sale or the machine Serial No 2 For claims under this guarantee contact the supplier from whom you purchased the product who will arrange the appropriate action Do not initially return the product as this could result in transit damage ...

Page 8: ...Type Cimex Model X46 Serial Number Year of Construction 2004 has been manufactured using the following transposed harmonized European Standards and technical specifications BS EN 60335 1 and BS EN 60335 2 67 and is in conformity with EC Directives 98 37 EC 73 23 EEC and 89 336 EEC and all amendments Signed in SOUTHAMPTON England on the 30th day of July 2004 Signature Name M R Eneas Position New Pr...

Page 9: ...9 ...

Page 10: ...10 ...

Page 11: ......

Page 12: ...Truvox International Limited Third Avenue Millbrook Southampton Hampshire SO15 0LE England Tel 44 0 23 8070 2200 Fax 44 0 23 8070 5001 e mail truvox truvox com Web www truvox com ...

Reviews: