Page | 9
Jumpers:
Jumper
Default
Purpose
JP-5
8-7 In
6-5
4-3
2-1
Provides 0dB of gain.
Provides 12dB of gain.
Provides 24dB of gain.
Provides 36dB of gain.
JP-8
Out
Adds 6 dB of attenuation to the Data In signal.
For use only in Balanced systems.
JP-9
Out
Adds 12 dB of attenuation to the Data In signal.
For use only in Balanced systems.
JP-10
Out
Adds 18 dB of attenuation to the Data In signal.
For use only in Balanced systems.
JP-11
In
Adds 6 dB of attenuation to the Data In signal.
For use only in Single Ended systems.
JP-12
Out
Adds 12 dB of attenuation to the Data In signal.
For use only in Single Ended systems.
JP-13
Out
Adds 18db of attenuation to the Data In signal.
For use only in Single Ended systems.
Jumpers JP-13, 12, 11, 10, 9 and 8 set up attenuation circuits. Only
one of these jumpers should be installed. JP-11, 12 and 13 are for
Single Ended systems and JP-10, 9 and 8 are for Balanced
systems.
Summary of Contents for C Plus I
Page 24: ...Page 24 SECTION 11 Schematics Data Input and Output...
Page 25: ...Page 25...
Page 27: ...Page 27...