Cillit CB-THERMOCYCLON 12 N Technical Information Download Page 3

3

Drawings and overall dimensions

s e a s o n a l

t o p p i n g u p o f

conditioners.

IQ - Quality Information:

perfect removal of oxides, muds
and impurities in general;
can also be used to filter muds
during the sanitizing of old
systems;
washing in counter-current using
water supply water without using
the system water containing
conditioners;
easy installation using fittings

already prepared;
tap to take samples of water
directly from the circuit;
fitting with valve to add and top up
conditioners required by DMiSE
26/06/2015;
appliance designed to resist the
pressure and temperature of the
water in the heating system.

C B - D E V I A T O R E

1 2

C O N

MAGNETE

,

is a patented connect-

ing fitting which allows, through a
diaphragm, efficiently deviating part

o f

t h e

w a t e r

t o

t h e

C B -

THERMOCYCLON filter allowing its
filtration, complete with removable
and cleanable magnet, placed
downstream of the diaphragm, for
the retention of ferrous particles that
a r e

n o t

d i v e r t e d

t o

C B -

THERMOCYCLON. Made of brass
with threaded fittings and cap for
magnet extraction.

l

l

l

l

l

l

l

Technical data

Max. operating flow rate

m /h

3

inches

-

°C

°C

bar

m /h

3

bar

0,5

0,35

25 N

12 N

1,0

50 N

CB-THERMOCYCLON

½"

½"

¾"

13-25

up to 12

26-50

80

80

80

5-40

5-40

5-40

5

5

5

1,5

1,0

3,0

2

2

2

Fittings

Number of apartments approx.

Max. temperature water

Environment temperature min./max.

Max. operating pressure

Backwash flow rate approx.

Min. backwash water pressure

CB-THERMOCYCLON 25 N

6

8

0

6

1

0

HOT WATER
INLET

WASHING
DISCHARGE

HOT WATER
OUTLET

WASHING
INLET

ø265

ø275

CB-THERMOCYCLON 12 N

HOT WATER
INLET

WASHING
DISCHARGE

HOT WATER
OUTLET

WASHING
INLET

ø215

ø200

530

465

CB-THERMOCYCLON 50 N

WASHING
DISCHARGE

WASHING
INLET

HOT WATER
INLET

HOT WATER
OUTLET

1000

1100

ø360

ø342

In accordance with the law

, the reproduction, even partial, of this brochure is prohibited and it remains the property of B

WT IT

ALIA - B

WT IT

ALIA reserves the right to modify its products - 11/17 - AL

.02.A.10 - DM - mail

Summary of Contents for CB-THERMOCYCLON 12 N

Page 1: ...pper head there are four manual valves for connection in derivation from the return pipes of the heating system as well as for connection of the water supply pipes used for the back washing of the filter and for connection to the drainpipe fig 1 On the head of the filters there is also a sphere tap to draw water from the circuit and a manual valve for topping up the conditioning product flushed aw...

Page 2: ...e specific instructions shown in the assembly and service manual supplied with the appliance if these are lost please request another copy Make sure that the present technical information is up to date eventually make reference to the site or request an update 5 Warnings 7 Descriptionforoffer 6 Legislations CB THERMOCYCLON12 25 50N l l l l l Protect the filter from cold weather and direct sunlight...

Page 3: ...aced downstream of the diaphragm for the retention of ferrous particles that a r e n o t d i v e r t e d t o C B THERMOCYCLON Made of brass with threaded fittings and cap for magnet extraction l l l l l l l Technical data Max operating flow rate m h 3 inches C C bar m h 3 bar 0 5 0 35 25 N 12 N 1 0 50 N CB THERMOCYCLON 13 25 up to 12 26 50 80 80 80 5 40 5 40 5 40 5 5 5 1 5 1 0 3 0 2 2 2 Fittings N...

Page 4: ...ertiquality Technical information available on the website This technical information takes into account the experience of the company and applies to normal use of the product according to the above description other uses must be authorized each time in writing For regular operation and maintenance of the systems an agreement should be made with our Technical Assistance Centres which are present n...