INSTALLATION, OPERATION AND SETUP
3-10
Manual 0-5280
!
WARNING
The Power Source must be turned off and unplugged from the mains supply before the Dead Man
Switch function is changed.
!
WARNING
If 4T operation is selected when using the Dead man Switch mode, the use of and observer is
recommended.
10. Process Selection Control
The process selection control is used to select the desired welding mode. Two modes are available, GTAW
(Lift TIG) and MMAW (Stick) modes. Refer to section 3.08 for GTAW (TIG) set-up details or section 4.04
for MMAW (stick) set-up details.
Note that when the unit is powered on the mode selection control will automatically default to LIFT TIG
mode. This is necessary so as to prevent inadvertent arcing should an electrode holder be connected to
the unit and mistakenly be in contact with the work piece during power up.
11. Thermal Overload Indicator
This welding power source is protected by a self resetting thermostat. The indicator will illuminate if the
duty cycle of the power source has been exceeded. Should the thermal overload indicator illuminate the
output of the power source will be disabled. Once the power source cools down this light will go OFF and
the over temperature condition will automatically reset. Note that the mains power switch should remain
in the on position such that the fan continues to operate thus allowing the unit to cool sufficiently. Do not
switch the unit off should a thermal overload condition be present.
The display will also show error code E-- in the event of an over current or over temperature.
A-11665
12. Shielding Gas Inlet
The Shielding Gas Inlet connection is used to supply the appropriate shiielding gas to the unit. Refer to
section 3.08 for GTAW (TIG) set up details.
!
WARNING
Only Inert Shielding Gases specifically designed for welding applications should be used.
13. On / Off Switch
This switch is used to turn the unit on/off.
14. Fan on Demand
The Transarc170i is fitted with a fan on demand feature. Fan on demand automatically switches the cooling
fan off when it is not required. This has two main advantages; (1) to minimize power consumption, and
(2) to minimize the amount of contaminants such as dust that are drawn into the power source.
Note that the fan will only operate when required for cooling purposes and will automatically switch off
when not required.
Summary of Contents for TRANSarc 130i
Page 6: ......
Page 18: ...INTRODUCTION 2 2 Manual 0 5280 transarc 170i Notes...
Page 42: ...Theory of Operation 5 2 Manual 0 5280 TRANSARC 170i Notes...
Page 68: ...TRANSARC 170i DISASSEMBLY PROCEDURE 7 8 Manual 0 5280 Notes...
Page 76: ...ASSEMBLY PROCEDURES 8 8 Manual 5280 TRANSARC 170i Notes...
Page 80: ...TRANSARC 170i KEY SPARE PARTS 9 4 Manual 0 5280 Notes...