TRANSTIG 220AC/DC AND 300AC/DC POWER SOURCE
Manual 0-5293
2-5
INTRODUCTION
2.10 Specifications
Description
TRANSTIG 220 AC/DC
TRANSTIG 300 AC/DC
Packed Power Source Part Number
W1007221
W1007301
Power Source Mass
13.4 kg
16.3 kg
Power Source Dimensions
H 326mm x W 185mm x D
483mm
H 326mm x W 185mm x D
483mm
Power Source Part Number
W1007221
W1007301
Cooling
Fan Cooled
Fan Cooled
Welder Type
Inverter Power Source
Inverter Power Source
Australian Standards
AS 60974.1-2006 /
IEC 60974-1
AS 60974.1-2006 /
IEC 60974-1
Number of Phases
1
3
Nominal Supply Voltage
240V +/- 15%
415V +/- 15%
Nominal Supply Frequency
50/60Hz
50/60Hz
Welding Current Range (STICK Mode)
10 – 170A
10 – 200A
Welding Current Range (TIG Mode)
3 - 220A
5 - 300A
Factory Fitted Plug Rating
15A
Not applicable
Effective Input Current (I
1eff
) (note2)
14.7A
11.6A
Maximum Input Current (I
1max
)
23.1A
17.1A
Generator Requirement (note4)
6kW (7.5 kVA @ 0.8PF)
13kW (16 kVA @ 0.8PF)
STICK (MMAW)
Welding Output, 40
º
C, 10 min.
170A @ 40%, 26.8V
140A @ 60%, 25.6V
120A @ 100%, 24.8V
200A @ 60%, 28.0V
170A @ 100%, 26.8V
TIG (GTAW)
Welding Output, 40
º
C, 10 min.
220A @ 40%, 18.8V
180A @ 60%, 17.2V
160A @ 100%, 16.4V
300A @ 30%, 22.0V
220A @ 60%, 18.8V
180A @ 100%, 17.2V
Open Circuit Voltage (VRD active)
<23V DC
<25V DC
Protection Class
IP23S
IP23S
Table 2-1: Power Source Specification
NOTE
Note 1: Due to variations that can occur in manufactured products, claimed performance, volt-
ages, ratings, all capacities, measurements, dimensions and weights quoted are approximate only.
Achievable capacities and ratings in use and operation will depend upon correct installation, use,
applications, maintenance and service.
Note 2: The Effective Input Current should be used for the determination of cable size & supply
requirements.
Note 3: Motor start fuses or thermal circuit breakers are recommended for this application. Check
local requirements for your situation in this regard.
Note 4: Generator Requirements at the Maximum Output Duty Cycle.
Due to large variations in performance and specifications of different brands and types of genera-
tors, Cigweld cannot guarantee full welding output power or duty cycle on every brand or type of
generator.
Some small generators incorporate low cost circuit breakers on their outputs. These circuit break-
ers usually will have a small reset button, and will trip much faster than a switchboard type circuit
breaker. This may result in not being able to achieve full output or duty cycle from the power source
/ generator combination. For this reason we recommend a generator that incorporates switchboard
type circuit breakers.
Summary of Contents for A-12030