6.2 Transarc
400S
Specifications
Description (Refer NOTE 2)
Transarc 400S
Product Part Number
625740
Cooling
Fan Force Cooled
Welder Type & Welding process
Heavy Duty,
Leakage reactance,
Manual Metal Arc Welding
Welding Power Source mass
88kg
Dimensions
H 545mm x W 520mm x D 1000mm
Manufactured to Australian Standard
AS1966
Number of Phases
Two phase
Nominal Supply Voltage
415V
Nominal Supply Frequency
50Hz
Effective Input Current
∇
32.0A
Flexible Supply Cable Size
6mm
2
, 32A Heavy Duty
Current Range
LO
HI
Maximum Input Current
48.5A @ 45% Duty Cycle
48.5A @ 45% Duty Cycle
Maximum Input Current for Short Circuit
71A
71A
Single Phase Generator Requirement
♣
20kVA
♣
20kVA
Three Phase Generator Requirement
♣
35kVA
♣
35kVA
Recommended Rated Outlet
32A
32A
Recommended Wire Fuse Size
40A
40A
Welding Current Range
50 - 330A
55 - 400A
Welding Current
280A @ 60% duty cycle
330A @ 45% duty cycle
340A @ 60% duty cycle
400A @ 45% duty cycle
Open Circuit Voltage
79V
54V
∇
The Effective Input Current should be used for the determination of cable size & supply requirements.
Motor start fuses or thermal circuit breakers are recommended for this application. Australian Standard
AS3000 permits the rating of the fuse or thermal circuit breaker protecting the circuit conductors, to be
double the outlet current rating for any circuit used exclusively for an electric arc welder. Check local
requirements for your situation in this regard.
♣
Generator Requirements at the Maximum Output Duty Cycle.
6.3 Plant
Contents
Description Transarc
Tradesman HD
Transarc 400S
Welding Power Source
9
9
Wheeling Kit
9
9
Operating Manual
9
9