Ciga SLD3 107 Instruction Manual Download Page 3

WARRANTY

1). The warranty period of this device is 12 months from the date of sale

and does not include batteries or devices that have been misused or
tampered with.

2). Please fill in the warranty page and return it to the manufacturer.

3). The address of the manufacturer is in the warranty certificate.

13

GENERAL INFORMATION

This instruction manual is intended to give general instructions and advice
on the operation of the automatic digital blood pressure monitor (device)
model SLD3 107. The device should be used in accordance with the
procedures contained in this manual and should not be used for purposes
other than those described. It is important to read and understand the entire
manual, in particular the section 

“TIPS ON TAKING YOUR BLOOD

PRESSURE”

, before use.

RECOMMENDED USE

This device is intended for the measurement of Systolic and Diastolic arterial
blood pressure and determining the pulse rate in adult patients, i.e. age 15
and above. The cuff will accommodate an upper arm circumference range
of 22 to 32 centimetres. Blood Pressure is measured over a range of 40 to
260 mm of mercury (Hg) and heart rate over a range of 40 to 160 beats/minute.

OPERATING PRINCIPLE

The cuff is wrapped around the arm and inflated with the help of an air
pump in the device. The device measures the fluctuations in the pressure
of the cuff produced by extension and contraction of the artery in the arm
in response to each heartbeat. These are converted into millimetres of
mercury (Hg), and are displayed as a digital value. This device may not
meet the specified accuracy if it is used or stored in temperature or humidity
conditions outside the parameters stated in the 

“SPECIFICATIONS”

section of this manual. There can be possible errors in the measurement in
patients with expressed arrhythmia. Consult your physician if you wish to
take a child’s blood pressure. 

ATTENTION!  Do not use cuffs other than

the original cuff supplied in this kit.

2

Summary of Contents for SLD3 107

Page 1: ...IFU SBPMON107...

Page 2: ...pply Maximum Power Consumption Memory Operation Conditions Temperature Relative Humidity Transportation Conditions Temperature Relative Humidity Dimensions and weight without cuff or case Size Weight...

Page 3: ...pressure and determining the pulse rate in adult patients i e age 15 and above The cuff will accommodate an upper arm circumference range of 22 to 32 centimetres Blood Pressure is measured over a rang...

Page 4: ...alified healthcare professional 3 TROUBLESHOOTING SYMPTOM If you cannot get correct measurements with methods above stop using the device and contact the Customer Care Line on 0800 0430318 Do not try...

Page 5: ...st not be laundered or ironed 11 4 3 The correct measurement of arterial pressure can be difficult in patients with deep arteriosclerosis a weak pulse and in patients with irregular heart beats In the...

Page 6: ...Make sure that the measurement location on the upper arm is at approximately the same height as the heart and that the forearm is extended naturally on the table and does not move 2 You may lie on yo...

Page 7: ...t the edge of the cuff into the metallic ring as shown in Fig 1 2 Put the cuff on the arm and position the tube on the inner arm Fig 2 If measurement on the left arm is difficult the right arm can be...

Page 8: ...the readings will appear on display Fig 4 6 Press the O I button of the device to switch off For further readings repeat all actions given in this section To obtain accurate results it is necessary t...