CIAS Elettronica S.r.l.
Ed. 1.1
Installation Manual
Page
64
of
70
PYTHAGORAS 2
5.3 Electronic Alignment
The alignment must be carried out each time for each single bi-optic, keeping in mind that the
transmitters not involved in the present alignment must be disabled, like shown in the following
fig.
Alignment procedure:
Steps
NEWTON II 50
NEWTON II 100
NEWTON II 200
TX column
RX column
TX column
RX column
TX column
RX column
1)
Switch 5 and 6 to OFF
-
-
2)
Switch 1 and 2 to ON
Alignment
-
Buzzer ON
-
Buzzer ON Buzzer ON Buzzer ON
The incoming signal level is proportional to the sound frequency
Constant
green LED
Constant
red LED
Constant
green LED
The incoming signal level is
proportional to the number of LED lit
(bargraph)
Heating switch inactive and forced heating off
TX column Newton II 50
TX column Newton II 100
TX column Newton II 200
Switch off the bi-optic
Turn switches 1, 2, 5 and 6 to ON
*
1
2
3
4
ON
O N
T
r
O
N
O N
O F F
4
3
2
1
A LIG N. C HA N NE L
T X
O N
O F F
M O D E
6
5
S w itc h 5 e t 6 :
s e le c t o p e ra tio n g m o d e
O N
D E L A Y
A
L
A
R
M
R X
ON
OFF
4
3
2
1
ALIGN. CHA NNEL
S w itc h 1 e t 2 :
a lig n m e n t m o d e
5 6
ON
MODE
OFF
5 6
ON
MODE
OFF
5 6
ON
MODE
OFF
5 6
ON
MODE
OFF
ALIGN.
1 2
ON
OFF
ALIGN.
1 2
ON
OFF
ALIGN.
1 2
ON
OFF
ALIGN.
1 2
ON
OFF
ALIGN.
1 2
ON
OFF
ALIGN.
1 2
ON
OFF
ALIGN.
1 2
ON
OFF
MODE
5
6
ON
OFF