CIAS Elettronica S.r.l.
Ed. 1.2
Installation Handbook
page
40
of
55
CORAL-S
RECEIVER TEST POINTS
Symbol Function
Tp 3
Measure of field signal 200 mVpp (Oscilloscope)
Tp 4
Measure of the Automatic Gain Regulator Voltage Value (V RAG)
Tp 10
Ground reference for instruments
RECEIVER FUNCTION SELECTION SWITCH
Symbol Function
SW1
Position 1 = Barrier Alignment
Position 2 = Acquisition of: Channel Number, Value of Received Field
and indication of Alignment Quality
Position 3 = Walk-Test and indication of alignment quality
Position 4 = Normal Functionality
RECEIVER SWITCHES TO SET THE WORKING-PARAMETERS
Symbol Function
SW4
Regulation of the anti-masking control sensitivity (“0” = Low sensitivity,
“F” = High sensitivity, Default “8”)
SW5
Barrier Sensitivity regulation (“0” = Low sensitivity, F High Sensitivity,
Default “7”)
SW6
Type of answer of the barrier intrusion
(Default = “5”)
0 = Very High Decrease of Sensitivity
Use this for very big targets
or very near to the heads (Tx and
Rx) targets.
(Big birds, cats that can jump near the heads ect.)
1 =High Decrease of Sensitivity
For
big targets or very near to the heads
Tx e Rx
2 = Medium Decrease of Sensibility
For big targets
or very near to the heads
Tx e Rx
3 = Decrease of Sensitivity
For big targets or very near to the heads Tx e Rx
4 = Decrease of Sensitivity Equal for every target
5 = Standard
6 = Increase of Sensitivity Equal for every target
7 = Increase of Sensitivity for small target
(intruder who crawls or rolls)
8 = Medium increase of sensitivity for small target
9 = High increase of Sensitivity
for small target
Summary of Contents for CORAL-S