Special instructions for safe use  

To reduce the risk of ignition of a flammable or explosive atmosphere, strictly adhere to the following Caution and 
Warning statements 

WARNING

 - DO NOT OPEN BACK COVER WHEN ENERGIZED 

 

The flame-path joints are not intended to be repaired. 

 

Models MetCam and MetCam Wi-Fi must be either connected to a SELV or PELV system, or directly connected 
to an apparatus compliant with IEC 60950 series, IEC 610101-1, or equivalent. 

 

Additional precautions and protection measures are necessary if the equipment is installed in a location of high 
risk of mechanical danger. 

 

The cable gland must be properly selected to suit the final application of the equipment and/or to maintain the 
protection method marked thereon. They must provide adequate ingress protection of IP54 as a minimum, or an 
IP66 when it is necessary such for the final application of the equipment. 

 

Tightening torque values are defined for the following: 

o

 

Set of hexagonal head screws (21 screws in total, 5/16" wrench) in the front plate flange joint:  
3.4 Nm (30 lb-in); 

o

 

Blanking element / stopping plug by International Metal Engineering 

– Singapore, model 89T20M; EX d 

IIC; IECEX SIR 07.0082X (if used): 55 Nm (40.6 lb-ft). 

 

These torque values shall be checked during the equipment installation and reapplied if necessary. 

 

Only enclosure fasteners supplied by CI Systems Ltd. (grade 5 steel screws; tensile strength equal to 110,000 
PSI or better) shall be applied. 

 

The threaded back plate shall be tightened all the way to the stopping shoulder and secured against self-
loosening by tightening the set screw (using hex 0.050"). 

 

Lens guards must always be applied and they must be properly seated. 

 

Only model of antenna and antenna coupler supplied by CI Systems L

td., as per manufacturer’s documentation, 

shall be used. 

 

3

Description 

 

3.1

Product Overview 

MetCam is manufactured by CI Systems Ltd, 6 HaMechkar St, Migdal HaEmek, Israel 

MetCam models A160100xxx0 are Methane imaging devices.  
These MetCam models are dedicated for the detection of Methane in its various forms as natural gas (NG), compressed 
natural gas (CNG) and liquefied natural gas (LNG).  

Address all correspondence and returns (EU) to CI Systems France, Phone: +33-1-4819-9797, Email: [email protected]
Address: 44 rue Maurice de Broglie 93600, AULNAY SOUS BOIS, France. 

Address all correspondence and returns (USA) to CI Systems Inc., Phone: +1-805-520-2233,  
Email: [email protected], Address: 1500 N. Interstate Highway 35, Suite C116, Carrollton, Texas 75006, USA. 

For all other worldwide locations please contact CI Systems Ltd., Phone: +972-4-644-8888,  
Email: [email protected], Address: 6 HaMechkar St, Migdal Ha'Emek 2306990, Israel 

MetCam performs three applications in parallel: 

 

Automatically warns on the presence of Methane clouds exceeding set thresholds 

 

Generates and stores to memory an hourly image of minute Methane emissions. 

 

Provides live video of the monitored area for situational awareness. 

 

3.2

Features 

 

Continuous automatic Methane leak detection 

 

Quantifies gas cloud concentration length and size 

 

Visualizes the gas cloud and source of leak on a visible image/video 

 

Preset warning and alarm levels 

Summary of Contents for MetCam A160100 0 Series

Page 1: ...MetCam Technical Manual Document P N A1604870010 1 MetCam Models A160100xxx0 Instructions for Use Manual Rev B Feb 2020...

Page 2: ...Type Marking 6 4 Use 7 4 1 Installation Prerequisites 7 4 1 1 Electrical Installation Prerequisites 7 4 2 Installation 8 4 2 1 Handling 8 4 2 2 Installing the Tilt Mount 9 4 2 3 Connecting MetCam to t...

Page 3: ...ocument P N A1604870010 3 5 Troubleshooting 14 6 Maintenance 14 6 1 Optical Cleaning Instructions 14 6 2 Exterior Cleaning Instructions 14 6 3 Periodic Procedures 15 7 Disposal 15 8 Technical Data 15...

Page 4: ...ational rules and regulations associated with this product Only trained and competent personnel who are familiar with local codes and practice are permitted to inspect repair and service the product a...

Page 5: ...d The threaded back plate shall be tightened all the way to the stopping shoulder and secured against self loosening by tightening the set screw using hex 0 050 Lens guards must always be applied and...

Page 6: ...as a supplementary detection device for total risk reduction The limitations of this technology must be assessed with respect to their ability or inability to determine the concentration of gas There...

Page 7: ...here is a significant likelihood of equipment personnel or moving objects accidentally knocking MetCam out of alignment should be avoided If such locations cannot be avoided measures including improve...

Page 8: ...and wire MetCam see Section 4 3 1 MetCam power up see Section 4 4 4 2 1 Handling Warranty void if opening MetCam enclosure other than the back cover used for accessing the electrical connections to th...

Page 9: ...mount is not symmetrical make sure to install it in the correct orientation Note that the tilt mount does not include a pan degree of freedom so it is important to align it to the monitored area when...

Page 10: ...eld optional item should be mounted after connecting MetCam to the tilt mount It does not interfere with wiring or with aiming MetCam 4 2 5 Installing the Wi Fi Antenna MetCam can be ordered with an o...

Page 11: ...the back of MetCam needs to be opened for accessing the terminal block and then needs to be closed properly so that the unit will retain its explosion flame proof certification The arrow in the pictur...

Page 12: ...vailable for connecting the cable shield on the cable gland entrance collar Terminal Block Pin Assignment Pin Marking on Terminal Block Description 1 Voltage input Max 32 V 2 Voltage input 3 4 20 mA H...

Page 13: ...cation of the Indicator LED the green arrow is pointing to it 4 5 4 20 mA Signaling and LED Status MetCam uses a stepped output and needs to be installed as a 4 wire transmitter The signaling range is...

Page 14: ...reflector periodically The frequency of cleaning operations depends upon the local environmental conditions and specific applications It is recommended to visually inspect and clean if deemed necessa...

Page 15: ...t be disposed of as household waste You can return this product to CI Systems free of charge For information please contact the national marketing organizations or CI Systems 8 Technical Data Mechanic...

Page 16: ...temperature range w o wifi A1601001340 Extended temperature range wifi M25 Gland Entrance MetCam Models P N Description A1601000200 Standard temperature range w o wifi A1601000240 Standard temperature...

Reviews: