08
3. Installation cautions
When transporting the product, do not tilt it over 45
°
.
※
Severe tilting can cause performance degradation.
Keep the product approximately 8" (20 cm) away from the wall for proper ventilation.
Use the following water quality range.
• Water pressure : 1.4~7 kgf/cm
2
(137~686 kPa)
• Water temperature : 39~100 °F(4~38 °C)
• pH : 5.8~8.5
•
Water hardness : 300 ppm or less
• Turbidity: below 0.5 NTU
•
Water quality : Biologically safe water quality
※
When using the water out of range, discuss it with the company. If not, the product can be excluded from
the stated warranty.
Do not connect hot water over 100
O
F(38
O
C) to this product.
※
This can cause trouble and decline in ice making performance.
When connecting tube, ensure that the tube is not bent or pressed down by heavy objects, etc.
* If tube is bent or pressed, water does not flow well and can cause problems.
The highest point of installed brine tube must be less than 12"(30 cm) away from the flat floor. Total length of brine tube
must be less than 118"(3 m). Otherwise, water is not drained well.
When installing more than one product(water purifier, shower softener, etc.), tubes of source water, brine water need
to be independent for one another.
Adjust the tube so that brine water may not splash around area.
* Brine water can easily be used for other purposes, such as bathroom cleaning, house cleaning, laundering,
washing, etc. Never use the brine water for drinking or cooking.
Do not install the product at the following places.
• Near fire or heater
• Near flammable material
• Wet place
• A place exposed to rain or snow
• In front of the cooling and heating device
• Near chemicals(volatile material, organic solvent, etc.)
• A place below 32 °F(0 °C) or a place with the possibility of dropping below 32 °F(0 °C).
• A place above 104 °F(40 °C) or a place with the possibility of rising above 104 °F(40 °C).
Install the product at a place where the surface is flat, and after installation, always adjust the level of the product by
using a level gauge. It is recommended to install the product on a sink band or table higher than 80cm above the floor.
*If the product tilts more than 3
o
, water overflow may occur.
Do not place any electric heater near the rear of the product.
1
2
3
4
5
6
7
8
9
10
11
Summary of Contents for EDGE CHP-3990DL