background image

Ref OP-0012-A April 2015 

Page 5 

 

2.4. Cancelation of user-code 

- Press «

ON

»; 

- Press «

ENTER

»; 

- Press «

0

»; 

- Press «

ENTER

»; 

- Enter valid master-code and press«

ENTER

»; 

The user code can only be cancelled by a valid master-code.  
 

 

2.5. Programming of Time delay and Opening window.   

The time delay (TD) function refers to the period of time which must elapse before the lock can be 
opened. 

The opening window (OW) is the period in which the lock may be opened after the TD has elapsed. Any 
valid code can be provided with a TD or OW function. 
- Press «

ON

»; 

- Press «

EN

» 

-Press 

«6»

-Press «

ENTER

» 

-Enter valid user code or master-code and press «

#

» 

-Enter a 2-digit number that will stand for the TD (01 -99 minutes) and a number for the OW (1-9 
minutes).   
For example: 092 – 9 minutes for TD, and 2 minutes – for the OW.  
- Press «

EN

»; 

 

Opening with the help of the programmed TD and OW.   

- Press 

«ON»

- Enter valid user-code or master-code: green visual LED  
- Automatic start of TD: red visual and acoustic signal and every 5 seconds  
- After end of TD – acoustic signal 
- Automatic start of OW: green visual and acoustic signal every 5 seconds  
-Enter valid code once again during OW: green visual signal 
-If the code is correct the device works as indicated step 3.1.1 or 3.1.2.  
By pressing «

ENTER

» during TD period this function is interrupted. The entire sequence must then be 

repeated in order to open again. 
 

 