MM-LF
09/06/18
®
™
INSTANT-FLOW MICRO MIX - LOW FLOW
ELECTRIC TANKLESS WATER HEATER - POINT OF USE
Get Started
www.mgispecbuilder.com
Configure products and create specs with ease.
SELECTION SUMMAR
Y
&
APPROV
AL
FOR
MANUF
ACTURING
Model Number & Options_____________________________________________________________________Quantity_______________
Company_______________________________________________________________________________________________________
Contact_________________________________________________Title____________________________________________________
Signature
(Approval for
Manufacturing)__________________________________________________________________Date ____________________________
PH. 800-447-4962
626-937-4270
FAX 626-937-4279
www.chronomite.com
TECHNICAL DIMENSIONS
INSTALLATION DIAGRAM
WIRING CONNECTION
"GRD" is
earth
ground.
Conduit
Refer to local
code for wire size
Hot or
Neutral
Hot or
Neutral
ATTENTION:
Unit must be hard wired.
NOTE: Heaters are single phase.
All tests are measured at
the output of the heater.
!
The microprocessor adjusts the heater's power for variations in flow
rates, inlet water temperature and pressure to assure the selected
factory preset water temperature.
!
GENERAL NOTES:
!
240V models when operated at 220V will have approximately a 15%
wattage decrease.
1/4"
9-5/8"
5-3/4"
ø 3/16", 4 Mounting Holes
1/4"
Front Service Panel
!
Microprocessor limits temperature increase according to the pre
selected temperature.
!
The combination of Chronomite’s IAPMO certified instantaneous
water heater and the Chronomite’s IAPMO certified valve assembly
AP-12, when installed per the instructions, complies with ASSE
1070. Reference: IAPMO R&T Certificate no. 7257.
Minimum Operating Flow Rate:
0.35 GPM
Housing Color:
White
INSTANT-FLOW
®
MICRO MIX™ - LOW FLOW
Weight:
6 lbs.
Maximum Pressure:
150 PSI
Minimum Operating Pressure:
25 PSI
Maximum Operating Temperature:
160°F
Listing:
UL, IAPMO, UPC, ADA, ETL
Dimensions:
6-1/4" (H) x 9-5/8" x 2-3/4"
Maximum Operating Pressure:
80 PSI
Materials: Rugged cast aluminum housing, Celcon
plastic element assembly with Nichrome
coils and AP-12 mixing valve assembly
Electrical
Knock-Out
Behind Unit
ø 1" Access Hole
1-1/8"
2-3/4"
10-1/8"
1-1/8"
1-5/16"
AP-12 Mixing
Valve Assembly
17-1/4"
Acorn Family of Companies
Micro Mix
Heater
J-Box
Mounting
Flanges (4)
3/8"
Cold Water
Faucet Feed
5/8" x 3/8" x 3/8"
Three Way Angle
Stop Valve
3/8" Cold Water Inlet
Note: Heater to be
installed below the level
of all hot water outlets
serviced by the heater
3/8" Hot
Water Faucet
Feed
Compression Fittings (2)
Chronomite Laboratories assumes no responsibility for use of void or suspended data. © Copyright Chronomite Laboratories, Inc.
Member of Morris Group International, City of Industry, CA Please visit
www.chronomite.com
for most current specifications.