TECHNICAL DIMENSIONS
INSTALLATION DIAGRAM
WIRING CONNECTION
"GRD" is
earth
ground.
Conduit
Refer to local
code for wire size
Hot
Hot or
Neutral
ATTENTION:
Unit must be hard wired.
NOTE: Heaters are single phase.
All tests are measured at
the output of the heater.
GENERAL NOTES:
¥
rates, inlet water temperature and pressure to assure the selected
factory preset water temperature.
¥
240V models when operated at 220V will have approximately a 15%
wattage decrease.
¥
120V models when operated 110V will have approximately a 15%
wattage decrease.
The microprocessor adjusts the heater's power for variations in flow
HOT
COLD
3/8" Hot Water Outlet
Compression
Fittings (2)
Instant-Flow
Micro Heater
J-Box
Mounting Flanges (4)
3/8"
Cold Water
Faucet Feed
5/8" x 3/8" x 3/8"
Three Way Angle
Stop Valve
3/8" Cold Water Inlet
Note: Heater to be
installed below the level
of all hot water outlets
serviced by the heater
1/4"
9-5/8"
5-3/4"
ø 3/16", 4 Mounting Holes
2-3/4"
2"
3-5/16"
ø 1" Access Hole
1-1/8"
2-3/4"
10-1/8"
1-1/8"
1-5/16"
HOT
COLD
6-1/4"
1/4"
Front Service Panel
Chronomite Laboratories, Inc.
City of Industry, CA 91744 U.S.A.
SELECTION SUMMAR
Y
&
APPROV
AL
FOR
MANUF
ACTURING
Model Number & Options_____________________________________________________________________Quantity_______________
Company_______________________________________________________________________________________________________
Contact_________________________________________________Title____________________________________________________
Signature
(Approval for
Manufacturing)__________________________________________________________________Date ____________________________
PH. 800-447-4962
626-937-4270
FAX 626-937-4279
www.chronomite.com
®
INSTANT-FLOW MICRO - LOW FLOW
¥
104°F factory preset setting temperature ; no mixing valve needed
¥
Factory setting of 110°F or above require cold water mixing at the
hand wash faucet.
¥
Microprocessor limits temperature increase according to the pre-
selected temperature.
Instant-Flow Micro is ideal for sensor/hands-free faucets with the
IFM-LF
03/17/15
®
INSTANT-FLOW MICRO - LOW FLOW
Dimensions:
6-1/4" (H) x 9-5/8" x 2-3/4"
Weight:
5 lbs.
Materials:
Rugged cast aluminum housing
Celcon plastic element assembly
with nichrome coils
Housing Color:
White
Minimum Operating Flow Rate:
0.35 GPM
Minimum Operating Pressure:
25 PSI
Maximum Operating Pressure
150 PSI
Maximum Operating Temperature:
140°F
Listing:
UL, IAPMO, UPC, ADA
Rear Electrical Knock-Out
Chronomite Laboratories assumes no responsibility for use of void or suspended data. © Copyright Chronomite Laboratories, Inc.
Member of Morris Group International, City of Industry, CA Please visit
www.chronomite.com
for most current specifications.
Downloaded from www.GadgetsGo.com, Authorized Chronomite Distributor