the battery capacity; if the battery 

capacity is still low, please contact 

with the agency. 

Battery fault 

Please contact with the agency for 

replacing the battery. 

 

Summary of Contents for UPS-HEATST-PSWL350W-CHR 10K

Page 1: ...1 USER MANUAL UPS Uninterruptible Power System Thank you for choosing CHROME Please read carefully the following instructions and keep them within reach Reorder No UPS HEATST PSWL350W CHR...

Page 2: ...ipment inserted to ensure that the total leakage current does not exceed 3 5mA It is absolutely not allowed to disconnect the main power wire of the UPS system during operation or disconnect the indoo...

Page 3: ...ep 1 UPS input wiring The socket for the UPS system must be the two pole three wire grounded socket and any extension wire should not be used It is suggested to use the power wire provided by the prod...

Page 4: ...e battery will be reduced Step 5 software installation In order to provide the most perfect protection for the computer you can install UPS monitoring software and finish relevant UPS settings You can...

Page 5: ...ion indicator lamp Back lamp switch ON Mute Turn on UPS press ON Mute button twice for more than two seconds to turn on the UPS system Turn off buzzer when the UPS system is under battery mode please...

Page 6: ...e pure AC power output and meanwhile charge the battery Battery mode When the input voltage is abnormal or the power is cut off the UPS system will be switched to the battery mode and meanwhile the bu...

Page 7: ...ith the agency LED5 lamp and LED6 lamp on the LED panel flicker at the same time and the buzzer sounds twice every one second UPS overload Please remove the overload part from the UPS output terminal...

Page 8: ...8 the battery capacity if the battery capacity is still low please contact with the agency Battery fault Please contact with the agency for replacing the battery...

Page 9: ...arge time should not be less than 12h in normal working environment the battery should be charged and discharged every four to six months and the continuous charge time should not be less than 12 hour...

Page 10: ...Output waveform Pure sine wave Efficiency AC power mode 85 Battery mode 83 Battery Battery voltage of long run time model 12VDC 36VDC 72VDC 96VDC Battery voltage of standard model 12VDC 24VDC 48VDC 7...

Page 11: ...orage transport treatment and recycling are important because they can avoid environmental pollution and are harmful to health Submitting waste electrical and electronic equipment to special collectio...