Chromatic HCV Valve Installation, Operation And Maintenance Manual Download Page 1

General Information

The  HCV  valve  is  a  quarter-turn  valve  with  a  segmented  sphere  or  Hemi  and  a  top  entry 
cartridge  design  that  fits  within  the  valve  housing  while  supporting  opposed  upstream  and 
downstream sealing components. The Hemi rotates around a stationary core which directs the 
flow through the valve. The Hemi sealing area, seat ring, and internal trim parts are not directly 
exposed to the flow stream when the Hemi is in the open position. The spherical offset Hemi 
design provides low pressure and low differential pressure sealing characteristics as well as 
increased capability to seal at high pressure. This design will increase the life of the seat insert 
by  reducing  its  mechanical  load  in  the  full  open  position.  The  spherical  offset  of  the  Hemi 
increases  the  sealing  forces  mechanically  in  the  closed  position  in  addition  to  the  pressure 
energized  piston  sealing  characteristic.  The  valve  is  bi-directional.  There  is  a  preferred  or 
normal flow direction which provides optimum sealing performance and seal life, especially in 
dirty  or  contaminated  fluids.  If  flow  and  pressure  are  in  the  non-  preferred  direction,  the 
pressure  energized  seat  ring  provides  sealing.  The  valve  internal  components,  such  as  the 
seat,  Hemi,  core,  seals,  and  bearings  are  all  contained  in  the  cartridge  assembly  and  the 
parallel machined body allows for easy installation and removal of the cartridge in the field with 
minimal time and effort. The valve can be provided with the operating options illustrated below. 
Other  options  are  available  upon  request.  Gears,  actuators,  and  levers  are  referred  to  as 
operators in the manual.

Storage

Inspect for any damage that may have occurred during shipment prior to storage and contact 
your shipper immediately if damages exist. Valves are drained and flange faces are coated with 
rust inhibitor and flange protectors are installed. Valves and actuation equipment protective 
covers  should  remain  in  place  until  the  valve  is  ready  to  be  installed  in  the  line.  Valves  and 
actuation  equipment  should  be  stored  inside  to  protect  them  from  harsh  environment 
including humidity and dust. Valves are shipped in the opened position, with the exception of 
Fail-Close systems, and should be stored in the as shipped condition. For special long term 
storage requirements on actuation equipment refer to applicable actuation manuals.

Unpacking

Remove any packing material, valve flange protectors, and protective covers from actuation 
equipment. Inspect the valve bore for foreign objects and, if necessary, clean the valve body. 
Handling equipment must be provided which is appropriate for lifting the valve and actuator 
assembly safely into position. Use slings, end flanges or eyebolts in the provided tapped holes 
on the valve. Do not use the lifting lugs or eyebolts on the actuator to lift the total assembly. Pay 
attention that slings or braces do not damage the actuator or gear.

Pre-installation Safety Information

The valves shall be installed, operated, and maintained in accordance with these procedures. 
Always follow standard safety procedure set forth by the law and regulations required by your 
employer,  end-users,  and  jurisdiction  authorities.  Any  transportation,  unpacking,  lifting, 
installation, operation, and maintenance of the system shall be made by expert, trained, and 
qualified personnel.

HCV

 

Valve

Installation, 
Operation, and 
Maintenance Manual

WARNING:

 

When lifting a valve with an attached actuator assembly, be aware that the center of 

gravity may be above the lifting point. Additional support must be provided to prevent the valve and 
actuator assembly from flipping or rotating. Failure to do so can cause serious injury to personnel 
and/or damage to the equipment.

Lever Operated

Adapted for Actuator

Gear Operated

Pneumatic/Electric Actuator

IOM HCV 001 09-2019A