6.5.2.12 Command FA (set ControlFlagsA)
The command FA is used to set the contents of XLC4 control register
ControlFlagsA
.
Command
Notes
CommandID
FA
Parameter
None
register value
HexChar
Parameter
Value
Description
None
If no parameter is defined, the command
responds with the current value for FA.
register value
0x0000
Default value
0x0001
Service
For service use only
– set to 0
0x0002
Internal
For internal use only
– set to 0
0x0004
ActSW
XLC4-1 and XLC4-1A:
Activate use of Switch
(SW1 to SW2 at connector X6)
0x0008
ActVO
Activate use of VOUT
(VOUT at connector X5)
0x0010
CheckFan Supervise Fan-valid signal
(ACNTRL at connector X5)
0x0020
Enable
ON
Activates flash function
(Signal ON at connector X6)
0x0200
Channel
control
mode
XLC4-1F4:
All channels are controlled
independent from the inputs at
X6
Response
fa , space , register value
General notes
The register value is applied after next power-up.
Combinations of single flags are possible.
Example:
FA 0x000C
# activates VOUT and SW1-SW2 for cooling device
fa 0x000C