Chromalox RTBC Installation Instructions Download Page 4

9 8   -   0 8 3

T A   -   X8 -   5 K

Litho in U.S.A.

Chromalox

®

P R O D U C T    S E R V  I C E

600 RIDGELY ROAD, MURFREESBORO, TN 37129

PHONE: (615) 848-2565                     FAX: (615) 848-2181

Chromalox warrants only that the Products and parts manufactured by Chromalox, when shipped, and

the work performed by Chromalox when performed, will meet all applicable specification and other specific
product and work requirements (including those of performance), if any, and will be free from defects in
material and workmanship under normal conditions of use. All claims for defective or nonconforming
(both hereinafter called defective) Products, parts or work under this warranty must be made in writing
immediately upon discovery, and in any event, within one (1) year from delivery, provided, however all
claims for defective Products and parts must be made in writing no later than eighteen (18) months after
shipment by Chromalox. Defective and nonconforming items must be held for Chromalox's inspections
and returned to the original f.o.b. point upon request. THE FOREGOING IS EXPRESSLY IN LIEU OF ALL
OTHER WARRANTIES WHATSOEVER, EXPRESS, IMPLIED AND STATUTORY, INCLUDING, WITHOUT
LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE.

Notwithstanding the provisions of this WARRANTY AND LIMITATION Clause, it is specifically under-

stood that Products and parts not manufactured and work not performed by Chromalox are warranted only
to the extent and in the manner that the same are warranted to Chromalox by Chromalox's vendors, and
then only to the extent that Chromalox is reasonably able to enforce such warranty, it being understood
Chromalox shall have no obligation to initiate litigation unless Buyer undertakes to pay all cost and expens-

es therefor, including but not limited to attorney's fees, and indemnifies Chromalox against any liability to
Chromalox's vendors arising out of such litigation.

Upon Buyer's submission of a claim as provided above and its substantiation, Chromalox shall at its

option either (i) repair or replace its Products, parts or work at the original f.o.b. point of delivery or (ii)
refund an equitable portion of the purchase price.

THE FOREGOING IS CHROMALOX'S ONLY OBLIGATION AND BUYER'S EXCLUSIVE REMEDY FOR

BREACH OF WARRANTY, AND IS BUYER'S EXCLUSIVE REMEDY AGAINST CHROMALOX FOR ALL
CLAIMS ARISING HEREUNDER OR RELATING HERETO WHETHER SUCH CLAIMS ARE BASED ON
BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORIES,
BUYER'S FAILURE TO SUBMIT A CLAIM AS PROVIDED ABOVE SHALL SPECIFICALLY WAIVE ALL
CLAIMS FOR DAMAGES OR OTHER RELIEF, INCLUDING BUT NOT LIMITED TO CLAIMS BASED ON
LATENT DEFECTS. IN NO EVENT SHALL BUYER BE ENTITLED TO INCIDENTAL OR CONSEQUENTIAL
DAMAGES AND BUYER SHALL HOLD CHROMALOX HARMLESS THEREFROM. ANY ACTION BY BUYER
ARISING HEREUNDER OR RELATING HERETO, WHETHER BASED ON BREACH OF CONTRACT, TORT
(INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORIES, MUST BE COMMENCED
WITHIN ONE (1) YEAR AFTER THE DATE OF SHIPMENT OR IT SHALL BE BARRED.

W2008M

WARRANTY AND LIMITATION OF REMEDY AND LIABILITY

21. FOR RTBC-EP ONLY:

Trim the blue (NORMALLY OPEN) thermostat wire so that it
is only 2 inches long. Tape over the end of the wire using
fiberglass tape.  See Figure 21.

22. FOR RTBC-EP WITH OVERCOATED CABLE ONLY:

Slide the bared end of the ground wire into the end of the
uninsulated barrel connector. Crimp it on using a crimping
tool. Slide the end of the braid pigtail into the other end of the
uninsulated barrel connector and crimp it on.  See Figure 22.

23. FOR ALL CABLE:

Mount terminal block to bottom of the box by driving the 6-32
self-tapping screw into the mounting hole as shown.  See
Figure 23.

24. FOR ALL CABLE:

Thread the screws into the outside pair of mounting holes of
the thermostat leaving approximately 1/8 inch of thread. Slide
the screws into the slots in the mounting bracket. Push the
thermostat down as far as it will go and tighten the screws
firmly.  See Figure 24.

25. FOR ALL CABLE:

Push the knob onto the shaft of the thermostat. Adjust thermo-
stat to desired temperature setting.  See Figure 25.

26. FOR ALL CABLE:

Carefully push wires into the box. Secure lid to box.  See
Figure 26.

27. FOR CABLE WITH EXPOSED METAL BRAID:

Unravel four inches of braid from the cable and twist into a pig-
tail. Connect to appropriate grounding source.  See Figure 27.

28. FOR ALL CABLE:

Extend capillary to allow bulb to be placed in desired location.
The bulb should be placed on the bottom half of the pipe
spaced 90˚ from the nearest heating cable or centered between
equally spaced heaters. Do not locate the bulb within 3feet of
a pipe support or other heat sink.

INSTALLATION

Figure 21

Figure 22

Figure 23

Figure 24

Figure 25

Figure 26

Figure 27

6-32 Screw

http://www.chromalox.com