REPLACEMENT PARTS FOR OCC AND WCC CONTROL CENTER (cont’d.)

Qty.

Description

Part Number

OCC or WCC-15-413, 480V, 1-3ø, 10 & 12 kW

1

Circuit Breaker, 480V, 20 Amp, 3 pole........................104-071818-018

1

Contactor, 600V, 20 Amp, 3 pole................................072-120812-005

2

Fuses, FNQ 1/2 (F1 and F2)........................................128-114696-010

1

Transformer, 150VA....................................................315-048507-018

OCC or WCC-15-423, 480V, 2-3ø, 20 & 24 kW

1

Circuit Breaker, 480V, 40 Amp, 3 pole........................104-071818-022

2

Contactors, 600V, 20 Amp, 3 pole..............................072-120812-005

2

Fuses, FNQ 6/10 (F1 and F2)......................................128-114696-005

6

Fuses, KTK-20 (F3 thru F8) ........................................128-047763-003

1

Transformer, 150VA....................................................315-048507-018

1

Time Delay Relay........................................................311-115540-001

OCC or WCC-10-433, 480V, 3-3ø, 30 kW

1

Circuit Breaker, 480V, 50 Amp, 3 pole........................104-071818-024

3

Contactors, 600V, 20 Amp, 3 pole ............................ 072-120812-005

9

Fuses, KTK-20 (F3 thru F11) ......................................128-047763-002

1

Transformer, 250VA....................................................315-048507-024

2

Time Delay Relay........................................................311-115540-001

2

Fuses, FNQ 6/10 (F1 and F2)......................................128-114696-005

Qty.

Description

Part Number

OCC or WCC-25-233, 240V, 3-3ø, 30 kW

1

Circuit Breaker, 240V, 100 Amp, 3 pole......................104-071818-014

3

Contactors, 600V, 30 Amp, 3 pole  ............................072-120812-005

9

Fuses, KTK-30 (F3 thru F11) ......................................128-047763-005

1

Transformer, 250VA....................................................315-048507-024

2

Time Delay Relay........................................................311-115540-001

2

Fuses, FNM 1- 4/10 (F1 and F2).................................128-114696-013

OCC or WCC-25-413, 480V, 1-3ø, 18 kW

1

Circuit Breaker, 480V, 30 Amp, 3 pole........................104-071818-020

1

Contactor, 600V, 30 Amp, 3 pole................................072-120812-001

2

Fuses, FNQ V2 (F1 and F2).........................................128-114696-010

1

Transformer, 150VA....................................................315-048507-018

OCC or WCC-25-423, 480V, 2-3ø, 36 kW

1

Circuit Breaker, 480V, 60 Amp, 3 pole........................104-071818-025

2

Contactors, 600V, 30 Amp, 3 pole..............................072-120812-001

2

Fuses, FNQ 4/10 (F1 and F2)......................................128-114696-010

6

Fuses, FRS-35 (F3 thru F8) ........................................128-121133-063

1

Transformer, 150VA ...................................................315-048507-018

1

Time Delay Relay........................................................311-115540-001

OCC or WCC-15-433, 480V, 3-3ø, 36 kW

1

Circuit Breaker, 480V, 70 Amp, 3 pole........................104-071818-026

3

Contactors, 600V, 20 Amp, 3 pole..............................072-120812-005

9

Fuses, KTK-20 (F3 thru F11) ......................................128-047763-003

1

Transformer, 250VA....................................................315-048507-024

2

Time Delay Relay .......................................................311-115540-001

2

Fuses, FNQ 6/10 (F1 and F2)......................................128-114696-005

OCC or WCC-30-213, 240V, 1-3ø, 12 kW

1

Circuit Breaker, 240V, 40 Amp, 3 pole .......................104-071818-007

1

Contactor, 600V, 30 Amp, 3 pole............................... 072-120812-005

2

Fuses, FNQ 8/10 (F1 and F2)......................................128-114696-011

1

Transformer, 150VA....................................................315-048507-018

OCC or WCC-20-413, 480V, 1-3ø, 15 kW

1

Circuit Breaker, 600V, 25 Amp, 3 pole........................104-071818-019

1

Contactor, 600V, 20 Amp, 3 pole................................072-120812-005

2

Fuses, FNQ V2 (F1 and F2).........................................128-114696-010

1

Transformer, 150VA....................................................315-048507-018

OCC or WCC-30-223, 240V, 2-3ø, 24 kW

1

Circuit Breaker, 240V, 80 Amp, 3 pole........................104-071818-012

2

Contactors, 600V, 30 Amp, 3 pole..............................072-120812-001

2

Fuses, FNM 8/10 (F1 and F2) .....................................128-114696-012

6

Fuses, FRN (F3 thru F8) .............................................128-121133-077

1

Time Delay Relay........................................................311-115540-001

1

Transformer, 150VA....................................................315-048507-018

OCC or WCC-20-423, 480V, 2-3ø, 30 kW

1

Circuit Breaker, 480V, 50 Amp, 3 pole........................104-071818-024

2

Contactors, 600V, 20 Amp, 3 pole..............................072-120812-005

Fuses, FNQ 6/10 (F1 and F2)......................................128-114696-005

6

Fuses, KTK-25 (F3 thru F8) ........................................128-047763-004

1

Transformer, 150VA....................................................315-048507-018

1

Time Delay Relay .......................................................311-115540-001

OCC or WCC-30-233, 240V, 3-3ø, 36 kW

1

Circuit Breaker, 600V, 125 Amp, 3 pole......................104-071818-045

3

Contactor, 600V, 30 Amp, 3 pole................................072-120812-005

9

Fuses, FRN 40 (F3 thru F11) ......................................128-121133-077

1

Transformer, 250VA....................................................315-048507-024

2

Relays, Time Delay .....................................................311-115540-001

2

Fuses, FNM 1- 4/10 (F1 and F2).................................128-114696-013

OCC or WCC-20-433, 480V, 3-3ø, 45 kW

1

Circuit Breaker, 480V, 70 Amp, 3 pole........................104-071818-026

3

Contactors, 600V, 20 Amp, 3 pole..............................072-120812-005

9

Fuses, KTK-25 (F3 thru F11) ......................................128-047763-004

1

Transformer, 250VA....................................................315-048507-024

2

Time Delay Relay .......................................................311-115540-001

2

Fuses, FNQ 6110 (F1 and F2).....................................128-114696-005

OCC or WCC-30-413, 480V, 1-3ø, 21 & 24 kW

1

Circuit Breaker, 480V, 40 Amp, 3 pole........................104-071818-022

1

Contactor, 600V, 30 Amp, 3 pole................................072-120812-001

2

Fuses, FNQ V2 (F1 and F2).........................................128-114696-010

OCC or WCC-25-213, 240V, 1-3ø, 3 & 8 & 10 kW

1

Circuit Breaker, 240V, 30 Amp, 3 pole........................104-071818-005

1

Contactor, 600V, 30 Amp, 3 pole................................072-120812-005

2

Fuses, FNQ 8/10 (F1 and F2)......................................128-114696-011

1

Transformer, 150VA....................................................315-048507-018

OCC or WCC-30-423, 480V, 2-3ø, 42 kW

1

Circuit Breaker, 480V, 70 Amp, 3 pole .......................104-071818-026

2

Contactor, 600V, 30 Amp, 3 pole................................072-120812-001

2

Fuses, FNQ 4/10 (F1 and F2)......................................128-114696-010

6

Fuses, FRS-40 (F3 thru F8) ........................................128-121133-064

1

Transformer, 150VA....................................................315-048507-018

1

Time Delay Relay....................................................... 311-115540-001

OCC or WCC-25-223, 240V, 2-3ø, 16 & 20 kW

1

Circuit Breaker, 240V, 70 Amp, 3 pole........................104-071818-011

2

Contactors, 600V, 30 Amp, 3 pole..............................072-120812-001

2

Fuses, FNM 8/10 (F1 and F2) .....................................128-114696-012

6

Fuses, KTK-30 (F3 thru F8) ....................................... 128-047763-005

1

Transformer, 150VA....................................................315-048507-018

1

Time Delay Relay........................................................311-115540-001

OCC or WCC-30-423, 480V, 2-3ø, 48 kW

1

Circuit Breaker, 480V, 80 Amp, 3 pole........................104-071818-027

2

Contactors, 600V, 30 Amp, 3 pole..............................072-120812-001

2

Fuses, FNQ 4/10 (F1 and F2)......................................128-114696-010

6

Fuses, FRS-45 (F3 thru F8) ........................................128-121133-065

1

Transformer, 150VA....................................................315-048507-018

1

Time Delay Relay........................................................311-115540-001

9

Summary of Contents for FXTH PN401

Page 1: ...3 3 4 5 1 4 1 FXTH 12015 127 WCC 40 213 WCC 20 413 18 43 22 14 27 1 5 1 4 1 FXTH 12718 170 WCC 45 213 WCC 25 413 21 51 25 14 30 1 5 1 4 1 FXTH 13021 190 WCC 55 213 WCC 30 413 24 58 29 14 32 1 5 1 4 1...

Page 2: ...during shipping Contact carrier if heater shows signs of damage Do not attempt to install heater if damage is evident Do not attempt to tighten or remove any of the threaded fittings in the flexible...

Page 3: ...on The heater must not be energized unless it is completely submerged 7 Machine manhole cover per Figure B or install optional terminal housing manhole adapter to manhole cover or storage tank per Fig...

Page 4: ...on under side of terminal housing C Bolt terminal housing to manhole cover or manhole cover adapter again using suitable gasket cement If manhole cover is machined per Figure B be sure to install copp...

Page 5: ...N All conduit con nections to terminal housing must be sealed to prevent entry of any water water vapor or condensation into terminal housing Breather tube length may be cut to shorten height or exten...

Page 6: ...o grounding lug in control box and from control box to a suitable ground 4 Connect power cable of proper voltage to input of control box 5 Secure control box door then place circuit breaker in on posi...

Page 7: ...thermocouples for a number of different gauges of wire By using this table it is necessary only to measure the length of the thermocouple knowing the type and gauge to determine its approximate resis...

Page 8: ...ter Flange 121 115692 001 Manhole adapter Housing 065 115693 001 Flange Gasket 132 115515 001 Housing Gasket 132 113661 001 Thermostat 300 115621 001 Thermocouple Probe 309 121168 001 Circuit Breaker...

Page 9: ...pole 072 120812 005 2 Fuses FNQ V2 F1 and F2 128 114696 010 1 Transformer 150VA 315 048507 018 OCC or WCC 30 223 240V 2 3 24 kW 1 Circuit Breaker 240V 80 Amp 3 pole 104 071818 012 2 Contactors 600V 3...

Page 10: ...40 001 OCC or WCC 40 233 240V 3 3 45 kW 1 Circuit Breaker 600V 150 Amp 3 pole 104 071818 046 3 Contactors 600V 60 Amp 3 pole 072 120812 002 9 Fuses FRN 45 F3 thru F11 128 121133 078 1 Transformer 250V...

Page 11: ...11...

Page 12: ...LVD LAVERGNE TN 37086 Phone 615 793 3900 www chromalox com Limited Warranty Please refer to the Chromalox limited warranty applicable to this product at http www chromalox com customer service policie...

Reviews: