CS3 Three Phase SSR Quick Start Manual
0037-75554 (PK528)
This manual is intended to provide only the basic installation and operation instruc-
tions for the CS3 Three Phase Solid State Relay. Please refer to manual PK522, for
complete installation & operation details. The most current revision of PK522 may be
found on the Chromalox website: www.chromalox.com
1. IMPORTANT SAFEGUARDS
ELECTRIC SHOCK HAZARD: Read and understand all instructions before
installing, servicing or operating this controller. Failure to do so could
result in equipment or property damage as well as personal injury and
even death.
HIGH VOLTAGE is used in the operation of this equipment. DEATH ON
CONTACT may result if personnel fail to observe safety precautions.
Learn the areas containing high-voltage connections when installing or
operating this equipment.
Be careful not to contact high-voltage connections when installing or
operating this equipment. Before working inside the equipment, turn
power off and ground all points of high voltage potential before touch-
ing.
ELECTRIC SHOCK HAZARD. Any installation involving control equip-
ment must be performed by a qualified person and must be effectively
grounded in accordance with the National Electrical Code to eliminate
shock hazard.
The Owner/Installer must provide all necessary safety and protection
devices and follow all current electrical wiring standards and regula-
tions. Failure to do so may compromise the integrity of the controller
and/or cause product failure resulting in a safety risk to operational
service and personnel.
This controller utilizes a heat sink which is designed to cool the unit
during operation. Under no circumstance should air flow around the
controller be compromised in any way. Failure to do so may result in the
overheating of the controller, product failure, product temperatures and
even fire.
During continuous operation, the heat sink can reach a very high tem-
peratures, and keeps a high temperature even after the unit is turned
off due to its high thermal inertia.
Higher voltages may be present. DO NOT work on the power section
without first disconnecting electrical power to the panel. Failure to do
so could result in serious injury or death.
2. INSTALLATION - MECHANICAL
To ensure proper performance, maximum safety and reliability, it is essential to install
the unit correctly. This includes proper mounting, spacing, hardware and wiring. See
below:
1. Maximum surrounding air temperature is 40°C in “Open Type Equipment” which
is suitable for use in pollution degree 2.
2. Install the unit vertically (max 10° inclination from vertical axis).
3. Spacing:
–Min. vertical distance between unit and panel wall: 3.9” (100 mm)
–Min. horizontal distance between unit and panel wall: 0.8” (20 mm)
–Min. vertical distance between adjacent power control units: 11.8” (300 mm)
–Min. horizontal distance between adjacent power control units: 0.8” (20 mm)
3. INSTALLATION – ELECTRICAL CONTROL, LOAD & LINE CONNECTIONS & LED INDICATION
CS3 with VDC Control Signal Input
CS3 with VAC Control Signal Input
Dimensions & Weights
1/L1
3/L2
5/L3
AC51: 25A
AC53a: 5A
CS3-02548-110
On
L1 L2 L3 A1+
T1 T2 T3 A2-
Alarm
B1
B2
A1
A2
2/T1
4/T2
6/T3
1/L1
3/L2 5/L3
AC51: 40A 600V ac
AC53a: 8A 50/60Hz
CS3-04060-112
On
L1 L2 L3 A1+
T1 T2 T3 A2-
Alarm
B1
B2
A1
A2
2/T1
4/T2 6/T3
5” (127)
5” (127)
8
1.18” (30)
3.94 (100)
1.97” (50) Max
3.15” (80)
8
CS3 25A
CS3 40A / CS3 55A
Depth:
- Models CS3-xxxxx-1xx: 5.9” (150)
- Models CS3-xxxxx-2xx: 6.2” (158)
2.4lb (1100 g)
3.0 lb (1350 g)
1.18” (30)
1/L1
3/L2
5/L3
AC51: 40A
AC53a: 8A
CS3-04060-221
On
1 3 5
A1+
2 4 6
A2-
Alarm
B1
B2
A1
A2
2/T1
4/T2
6/T3
20-260
VAC/VDC
600 VAC
50/60 Hz
fan: 230 VAC
nc
nc
Out
AI
1/L1
3/L2
5/L3
AC51: 40A
AC53a: 8A
CS3-04060-111
On
1 3 5
A1+
2 4 6
A2-
Alarm
B1
B2
A1
A2
2/T1
4/T2
6/T3
5-32 Vdc
600 VAC
50/60 Hz
fan: 230 VAC
Label
Connection/Indication
Label
Connection/Indication
L1, L2, L3 Line 1, Line 2, Line 3 VAC Input
B2
Alarm Output (Option)
T1, T2, T3 Load 1, Load 2, Load 3 VAC Input
ON
Red LED - Command Signal Indication
A1
(+) VDC Control Signal Input
Alarm
Yellow LED - Over Temp. Indication
A2
(-) VDC Control Signal Input
GND
Earth Ground (Not shown, varies by model)
B1
Alarm Output (Option)
Label
Connection/Indication
Label
Connection/Indication
L1, L2, L3 Line 1, Line 2, Line 3 VAC Input
ON
Red LED - Command Signal Indication
T1, T2, T3 Load 1, Load 2, Load 3 VAC Input
Alarm
Yellow LED - Over Temp. Indication
A1, A2
AC Control Signal Input
OUT-AL Red - LED Load/Line Interrupt Alarm
(Alarm Code 2 Only)
B1
Alarm Output (Option)
GND
Earth Ground (Not shown, varies by model)
B2
Alarm Output (Option)