Programmable Bidirectional DC Power Supply 62000D Series
Operating and Programming Manual
5-28
<Arg2>: Minute (NR1) 0 ~ 59
<Arg3>: Second (NR1) 0 ~ 59.99
Example:
PROG:SEQ:TIME 10
Query Syntax:
PROG:SEQ:TIME? [{MAX/MIN}]
Return Parameter:
<Arg1><,><Arg2><,><Arg3> same as the parameter.
Query Example:
PROG:SEQ:TIME?
Return Example:
1.01
5.6.2.8
SYSTEM Subsystem
1.
SYSTem:ERRor?
Description:
Returns error message and code of power supply.
Query Syntax:
SYSTem:ERRor?
Return Parameter:
aard
Query Example:
SYST:ERR?
Return Example:
-
203, “Data out of range”
Table 5-8
Code
Error Message
Code
Error Message
0
"No error"
-101
"Invalid character"
-102
"Syntax error"
-103
"Invalid separator"
-104
"Data type error"
-105
"GET not allowed"
-106
"Illegal parameter value"
-108
"Parameter not allowed"
-109
"Missing parameter"
-112
"Program mnemonic too long"
-113
"Undefined header"
-121
"Invalid character in number"
-123
"Numeric overflow"
-124
"Too many digits"
-131
"Invalid suffix"
-141
"Invalid character data"
-148
"Character data not allowed"
-151
"Invalid string data"
-158
"String data not allowed"
-202
"Setting conflict"
-203
"Data out of range"
-204
"Too much data"
-211
"Data stale"
-224
"Self-test failed"
-225
"Too many errors"
-226
"INTERRUPTED"
-227
"UNTERMINATED"
-228
"DEADLOCKED"
-229
"MEASURE ERROR"
-230
"Sequence overflow"
-231
"Sequence selected error"
2.
SYSTem:MODE
Description:
Sets the Source/Load output mode of the system.
Syntax:
SYSTem:MODE SOURCE-LOAD
SYSTem:MODE SOUR
SYSTem:MODE LOAD
Parameter:
SOURCE-LOAD | SOUR | LOAD
Example:
SYSTem:MODE SOURCE-LOAD
Query Syntax:
SYSTem:MODE?
Return Parameter:
Source&Load | Source | Load
Query Example:
SYSTem:MODE?
Return Example:
Source&Load
3.
SYSTem:VERSion:INTernal?
Description:
Queries the Host version.
Summary of Contents for 62000D Series
Page 1: ......
Page 2: ...Get more information by downloading Chroma ATE Solutions APP ...
Page 8: ...vi ...
Page 9: ...vii ...
Page 10: ...viii ...
Page 14: ......
Page 18: ......
Page 35: ...Overview 1 17 Figure 1 6 Dimension of 62000D 600 1200 1800 Models ...
Page 36: ......
Page 52: ......
Page 63: ...Manual Operation 3 11 Figure 3 13 Figure 3 14 ...
Page 109: ...Manual Operation 3 57 _EXT ON SIGNAL EXT ON DISABLE EXT ON ENABLE Output Output Figure 3 85 ...
Page 110: ......