26
Training area in mm
(for home trainer and user)
Free area in mm
(Training area and security area
(rotating 60cm))
TIPS
1.
Operationally, the ergometer with generator has got in different speeds
a little more or less rough construction noise, which is normal.
2.
Keep moisture away from computer.
3.
The USB port socket on side of the computer can use for charging of
small devices during exercising.
The loading data are 5V / 0.35A-1A
4.
An accumulator pack with 6V/1300mAh is located in the accu compart-
ment at backside of computer. For replacement, open the accu compart-
ment, remove the accu pack, disconnect and replace it with an identical
model. The lifetime of accu depends on the charging frequency.
Pulse Rate:
1. Hand pulse measurement:
On the left and right handlebar grip part two metal contact plates are insert
as pulse sensors. Please take care that both hands at the same time in
normal force on the sensors. During the heartbeat measurement a heart
symbol flashes next to the pulse display.
(The hand pulse measurement serves only for orientation, as it is caused
by movement, friction, sweat etc. it can come to deviations from the actual
pulse. A few people may cause malfunctions of hand pulse measurement.
Should you have trouble with the hand pulse measurement, we recom-
mend the use of a cardio chest belt.)
„WARNING“
Heart rate monitor systems may be inaccurate. Excessive
exercising can lead to serious damage or maybe to death. If dizziness or
weakness is felt, stop exercising immediately.
2. Cardio - Pulse Measurement:
On the market, cardio pulse measurements are available, which consist
of a transmitter chest belt and a watch receiver or only chest belt. The
computer of your Ergometer has build in receiver (without sender) and with
using a suitable chest belt for cardio pulse measurement the computer can
show the pulse data.
This works with all un-coded chest belts with transmission frequency is
between 5.0 - 5.5 kHz. The range of the transmitters depends on the model
approx.. 1m.
ATTENTION:
If both pulse measuring methods are used simultaneously
Hand pulse measurement takes precedence.
Cleaning, Checks and Storage of the Ergometer
bike:
1. Cleaning
Use only a less wet cloth for cleaning.
Caution:
Never use benzene,
thinner or other aggressive cleaning agents for surface cleaning as
this damage caused.
The device is only for private home use and for use suitable indoors.
Keep the unit clean and moisture from the device.
2. Storage
Choose a dry storage in-house and put some spray oil at front &
rear foot tube connection point and hand grip axle. Cover the bike to
protect it from being discolor by any sunlight and dirty through dust.
3. Checks
We recommend every 50 hours to review the screw connections for
tightness, which were prepared in the assembly. Every 100 operating
hours, you should put some spray oil at front & rear foot tube con-
nection point and hand grip axle.
Troubleshooting
If you cannot solve the problem with the following information,
please contact the authorized service center.
Problem
Possible Cause
Solution
Computer does
not switch
on after start
cycling.
Generator
voltage missing
base on not well
plugged connec-
tion.
Check the plug connections at
computer and inside of hand-
lebar support. Take off the left
cover if necessary and check
the plug connections there.
Computer is
not counting
data and do not
switch on after
start cycling.
Sensor impulse
missing base on
not well plugged
connection
Check the plug connections at
computer and inside of handle-
bar support.
Computer is
not counting
data and do not
switch on after
start cycling.
Sensor impulse
missing base on
not correct posi-
tion of sensor.
Take off the cover and check
the distance between magnet
and Sensor. The magnet at
turning belt wheel should have
only less than < 5mm distance
against the sensor position.
No pulse value
Pulse cable is
not plugged in.
Check the separately pulse
cable is well connected with
computer.
No pulse value
Pulse sensors
not well connec-
ted
Screw out the screw for pulse
measurement and check if
plugs are well connected and no
damage at pulse cable.