![Christie Spyder X80 Technical Reference Download Page 64](http://html.mh-extra.com/html/christie/spyder-x80/spyder-x80_technical-reference_2603498064.webp)
Commands
X80 Serial Commands Reference
64
020-102207-08 Rev. 1 (10-2020)
Copyright
©
2020 Christie Digital Systems USA Inc. All rights reserved.
OCB–Output Configuration Blending
Enables or disables the blending on a Spyder output.
Additionally, the blend width, type, and curve parameters can be adjusted.
Syntax
OCB <OutputID> <Edge> <Enable> <BlendWidth> <Mode> <Curve1> <Curve2>
Response
<Result Code>
page
for additional information on Result Codes
.
Arguments
Argument
Description
Values
<Output>
Sets the ID of the output to configure.
Zero-based
<Edge>
Sets the edge of the blending area of the
output.
L = Left
R - Right
<Enable>
Enables or disables the blending of the
output.
0 = Disables the blending of the output
1 = Enables the blending of the output
<BlendWidth>
Sets the width of the blend in pixels.
—
<Mode>
Sets the mode of the blend.
Bezier Gamma Velocity
<Curve1>
Sets the curve parameter 1.
0.000 to 1.000
<Curve2>
Sets the curve parameter 2.