background image

LW555 & LX505-605 Lamp-Filter Replacement Instruction Sheet

3 of 4

020-000239-03  Rev. 1  (07-2010)

REPLACING THE FILTER CARTRIDGE 

The filter prevents dust from accumulating on the optical 
elements inside the projector. Should the filter becomes clogged 
with dust particles, it will reduce the cooling fans’ effectiveness 
and may result in internal heat buildup and adversely affect the 
life of the projector. This projector has an electrically operated 
filter which helps you to replace the filter easily. The projector 
monitors the condition of the filter at all times and automatically 
scrolls to anew a filter when it detects clogging. 
If the projector detects that the filter is clogged and no scroll is 
left in the filter cartridge, a Filter cartridge replacement icon 
appears on the screen and the WARNING FILTER indicator on 
the top panel lights up. When you see this icon, replace the filter 
cartridge and reset the Filter counter and the Scroll counter. 
1. Turn off the projector, and unplug the AC power cord from 

the AC outlet. 

2. First, clean up the dust on the projector and around the air 

vents.  

3. Press 

 downwards on the filter cover to release the latch 

and open the filter cover.

4. Pull out the filter cartridge. When taking out the filter 

cartridge, put your finger on the tab and then pull.  

5. Insert new filter and close the filter cover. Make sure that the 

filter cartridge is properly and fully inserted.  

6. Connect the AC power cord to the projector and turn on the 

projector.  

7. Reset the filter counter and the scroll counter (see next page).  

NOTICES!

 

Make  sure  the filter cartridge is inserted in the 

projector. If the filter cartridge is not inserted, the projector 
cannot be turned on. Make sure the filter cover is closed when 
using the projector.  Do not put anything into the air vents. Doing 
so may result in malfunction of the projector.

  

We recommend avoiding dusty/smoky environments when operating the projector. Usage in these 
environments may cause poor image quality. When using the projector under these conditions, dust 
may accumulate on a lens, liquid crystal panels, or optical elements inside the projector. When the 
symptoms above are noticed, contact your authorized dealer or service station for proper cleaning.

ORDER REPLACEMENT FILTER    

Type No.

Service Part No.

003-003084-01

6103469034

Reviews: