background image

Q Series Lamp Hot Swap Instruction Sheet

1

020-101356-01 Rev. 1 (03-2014)

Q Series Lamp Hot Swap 
Instruction Sheet

This document provides instructions for replacing a Q Series lamp using the hot swap method. 

Safety Precautions

Tools and Hardware Required

• DWU951, DWX951, and DXG1051 replacement lamp (PN: 003-004774-XX)

• #2 Phillips screwdriver

Hot Swap Procedure Timing

The hot swap procedure must be completed in three minutes or the hot swap command is canceled 
and the projector shuts down. The hot swap countdown is initiated when the first lamp cover screw is 
loosened. The countdown completes when the lamp door is re-attached with its two screws 
tightened.

Failure to comply with these safety precautions results in death or serious injury.

• Lamp replacement must be performed by a Christie authorized service technician. 
• Never attempt to remove the lamp when hot. The lamp is under a great deal of pressure 

when hot and may explode, causing personal injury or death and/or property damage. 
Allow the lamp to cool completely before handling.

• Always wear manufacturer approved protective safety clothing (gloves, jacket, face 

shield) whenever the lamp door is open or when handling the lamp. Only qualified 
technicians should install projector lamps.

• If the lamp is blown out, do not perform this procedure.

Failure to comply with these safety precautions could result in death or serious injury. 

• Possibly hazardous optical radiation emitted from this product. (Risk group 3)
• Thermal radiation emitted from this product may cause burns. (Risk group 3)
• Do not insert your hand or tools into the lamp house while the lamp is removed.

Do not look straight into the ignited lamp or strongly lighted portion after the lamp is 
removed. Failure to comply with this safety precaution might cause decreased vision or loss 
of sight.

Reviews: