5
■
Power supply
6. Operation
-
Connect the power cord to the driver as shown below, twist the knob on the power cord to secure it onto
the driver. Do not force the connection, this may cause damage to the driver and power cord.
-
To avoid accident and injury, check driver’s torque setting, and make sure that the work piece is fixed
firmly before operating.
-
Change torque settings: Remove the torque cover and use the regulating handle to set the torque. Turning
it clockwise into the casing will increase the torque. Turning it counterclockwise out of the casing will
decrease the torque.
Note: The engraved markings on the engraving ring are for reference only and does not indicate
actual torque output. Torque output can only be determined by repeated testing with a torque meter.
To prevent your torque setting from being tempered, optional torque cover is available, which covers
and secures the regulating handle.
Model
Volume (mm)
Load Voltage
(AC)
Output
Voltage
(DC)
Weight
(g)
Safety Approved
Feature
Length Width Height
APS-301A 164 64 42 100-240V 20-30V 300
CB,CE,UL(CUL),
ROHS,REACH
Adjustable
stepless output
voltage
Available Input
Voltage
110-240VAC
Automatic device
application
AM-30 172 84 61 100-240V
20-30V
450
CB,CE,UL(CUL),
ROHS,REACH
Screw fastening
check
Screw counting
The illustration of torque setting