Installation

3

MF2486A

Poultry Application

Switch assembly/Installation

See 

“Switch Location” on page 4

 for Switch Height Information.

The Switches are designed for easy removal for Switch adjustment or for house clean-out.

Drop Tube location

Installation

Figure 1.Installation

Item Description

Part No.

1

Hopper Level Control Mounting Bracket

2911

2

1/4-20 x .50 Bolt

1487

3

1/4-20 Nut

751

Drill 9/32" [7mm] Holes
in Hopper. Use the 
Mounting Bracket for a 
Template.

1

Drill 9/32" [7mm] 
Holes in Hopper. Use 
Mounting Bracket 
for a Template.

1

2

2

3

Configuration for Mounting lower in Hopper

Configuration for Mounting Higher in Hopper

3

Item Description

Part No.

1

Hopper Level Control Switch

56284

2

Drop Tube

--

1

Install Drop Tube centered in Hopper but not 
directly over the Switch to avoid feed piling up 
at the Switch location 

as shown

.

Install Drop Tube just

below The top of the

Hopper.

2

Figure 2.Drop Tube location

Summary of Contents for Hopper 56284

Page 1: ...rical Hazard Disconnect electrical power before inspecting or servicing equipment unless maintenance instructions specifically state otherwise Ground all electrical equipment for safety All electrical...

Page 2: ...ch assembly Installation 3 Drop Tube location 3 Switch Location 4 Single Switch Application 4 Multiple Switch Application 4 Switch Adjustment 5 Hog Application 5 Wiring 6 Switch 6 DANGER Electrical Ha...

Page 3: ...x 50 Bolt 1487 3 1 4 20 Nut 751 Drill 9 32 7mm Holes in Hopper Use the Mounting Bracket for a Template 1 Drill 9 32 7mm Holes in Hopper Use Mounting Bracket for a Template 1 2 2 3 Configuration for M...

Page 4: ...ultiple Switch Application Hopper Level Switches may be placed in more than one Hopper to ensure that no Hopper empties before the Control Unit Hopper requires feed All Switches must be wired in paral...

Page 5: ...r For More Time Turn the Time Delay Adjustment Screw clockwise light blinks slower Hog Application In most Hog installations The Hopper Level Control is located in the Feeder at the end of the Fill Sy...

Page 6: ...rwise Ground all electrical equipment for safety All electrical wiring must be done by a qualified electrician in accordance with local and national electric codes Ground all non current carrying meta...

Page 7: ...rt Bracket 42612 10 Danger Decal 2527 35 11 Pan H SFTP 6 32 Screw 35493 12 10 x 5 HXWH Screw 28075 Item Description Part No 13 6 32 x 3 8 Phil Pan H Screw 34660 14 188 x 438 x 051 Washer 149 15 5 x 1...

Page 8: ...anual 34356 Contact your nearby Chore Time distributor or representative for additional parts and information Chore Time Group A division of CTB Inc PO Box 2000 Milford Indiana 46542 2000 USA Phone 57...