background image

                                               For additional manuals or more information, see our website at 

www.ctbinc.com

 

24 

 
 
 
 
 

 

 
 
 
 
 
 
 

Summary of Contents for Generation 2 QUADRATHERM QUADRADIANT

Page 1: ...es inasmuch as such changes result in content that is different from the authoritative CTB published English version of the manual For current product installation and operation information please contact the customer service and or technical service departments of the appropriate CTB subsidiary or division Should you observe any questionable content in any manual please notify CTB immediately in ...

Page 2: ... applies only to systems for the care of poultry and livestock Other applications in industry commerce or residential applications are not covered by this Warranty and are strictly prohibited Any such use will void the Warranty Manufacturer shall not be liable for any Consequential or Special Damage which any purchaser may suffer or claim to suffer as a result of any defect in the product Conseque...

Page 3: ... and may temporarily exist at floor level DO NOT ALLOW POWER CORDS AND OR GAS SUPPLY HOSES TO REST ON THER CANOPY HANGING BRACKETS OR OTHER HOT SURFACES OF THE UNIT OR TO COME WITHIN 12 OF THE HEATER DSI UNITS MUST BE PROPERLY GROUNDED DO NOT ALTER ELECTRICAL CORD Plug in the three prong power cord to a correctly grounded three prong electrical outlet The installation of this appliance must in all...

Page 4: ...g normal operation of the heater DO NOT install electrical wiring water lines or conduit above the heater DO NOT run gas supply hoses above the heater DO NOT ALLOW ANYONE WHO HAS NOT READ THESE INSTRUCTIONS TO INSTALL ASSEMBLE LIGHT ADJUST OR OPERATE THIS HEATER THIS HEATER IS TO BE INSTALLED BY CERTIFIED INSTALLERS ONLY ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THESE INSTRUCTIONS SHOULD USE OR S...

Page 5: ...G GAS PRESSURE EXCEEDING 10 WC FOR LP OR 5 WC FOR NATURAL GAS MAY VOID WARRANTY USE THREADED GAS CONNECTIONS ONLY HEATER MUST BE CONNECTED TO GAS SUPPLY USING THE DRIP LEG HOSE AND CONNECTORS PROVIDED WITH THE UNIT BY THE MANUFACTURER ALLOW HEATING UNIT TO COOL BEFORE WINCHING CLEANING OR SERVICING DO NOT ALLOW GAS HOSES OR POWER CORDS TO TOUCH HOT SURFACE DO NOT TOUCH HOT EMITTER PANELS BEFORE US...

Page 6: ...on manual 6 Heat Shields Q Have you installed all the heat shields on all of the heaters A See page 11 in the installation and operation manual 7 Sensor Location Q Have you positioned your temperature sensor correctly A See page 17 in the installation and operation manual 8 Hanging Q Are your heaters hanging points positioned properly and are all heaters hanging level A See page 10 11 14 in the in...

Page 7: ...e instructions in this manual can result in serious personal injury or property damage Horizontal Inlet Vertical Inlet GAS FLOW GAS FLOW GAS FLOW GAS FLOW Attach to main gas supply here Attach the certified and approved BLACK high pressure gas hose supplied with unit here to supply fuel to unit For Component list see page 23 CAUTION Purge gas supply line of any contaminants before attaching the sw...

Page 8: ...t www ctbinc com 8 Control Installation 5 Remove boot from igniter 4 Secure with two screws 8 Slide boot onto igniter wire 6 Slide boot onto igniter wire 3 Slide control onto burner 1 Remove tape bag of screws 2 Align burner and control 7 Connect wire to igniter ...

Page 9: ...The gas supply inlet must be installed so that the gas supply hose is away from the surface of the heater Electrical supply must be installed so that electrical power cord is away from the surface of the unit The gas supply hose and the electrical power cord must not touch or rest on any surface of the heater during operation of the unit or rest on the unit while the heater is being winched up or ...

Page 10: ...ater must be located so there is a minimum clearance to combustible material of 24 minimum of 12 if the heat deflectors are used above the heater and 48 from the side The heater should be hung with a minimum of 72 from the bottom of the heater and the floor We require a minimum clearance of 12 from the heater to the fuel and electricity supply lines The installer MUST comply with all applicable lo...

Page 11: ...o rest on the canopy hanging brackets or other hot surfaces of the unit or within 12 of the heater Failure to follow these instructions could result in serious personal injury of significant property damage WARNING Failure to follow the instructions in this manual could result in serious personal injury or property damage WARNING Failure to comply with all applicable local state and federal gas co...

Page 12: ...see our website at www ctbinc com 12 Each Unit requires two Left Deflectors and two Right Deflectors NOTE Narrow holed side of the deflectors face toward the outer side of the heater NOTE Full side of deflectors face to the center of the heater ...

Page 13: ...inc com 13 Align tabs of deflectors with slots on heater and insert tab into slots completely so that deflectors are flush against unit Using pliers bend the tabs to secure deflectors to the heater Bend these tabs toward the outer edge Bend these tabs towards the inside ...

Page 14: ...d or in conduit NOTE During and after winching make certain that ALL hoses and power supply cords are NOT resting on the heater nor are within 12 of the heater Pulley should be mounted in the ceiling and positioned 6 wider than the suspension points n the heater Cable Suspension Chain and Carabiner Suspension Cable Suspension Chain and Carabiner Suspension ...

Page 15: ...gas supply hose is touching the heater More of the hose will rest on the heater during winching THIS HOSE INSTALATION IS WRONG The gas supply hose is touching the heater More of the hose will rest on the heater during winching THIS HOSE INSTALATION IS WRONG The gas supply hose will rest on the heater during winching ...

Page 16: ...rom the regulator and connect the pressure gauge to the Pressure Tap on the side of the control See below Turn ON only the heater you are testing or if you have a zone system turn ON all the heaters in the zone Set the pressure at a Maximum of 10 WC LP gas or 5 WC NAT gas SECOND Turn ON all stoves in the house on the same regulator and check the pressure again The pressure should not drop below 9 ...

Page 17: ...s 5 Cut outer insulation ONLY on romex over each brooder to expose black and white wires DO NOT OR STRIP WIRES Bare ground wires in not used 6 Using T tap connectors connect wire from brooder valve 24V to romex white to white black to black Note cut off excess wire from valve 7 Connect together in junction box using wire nuts a Black from Power Supply Black to next junction box if used Black from ...

Page 18: ...ner BLOW OUT AND OFF the burner and complete unit with a leaf blower or compressed air after loosening the dust FOR WASH DOWN APPROVED MODELS ONLY POWER WASH DOWN INSTRUCTIONS MAXIMUM WATER PRESSURE 2 600 PSI 2 3 gpm nozzle Fan Type minimum 25 degree DISTANCE FROM NOZZLE TO PARTS 12 to 18 inches TURN OFF GAS SUPPLY AND DISCONNECT ELECTRICAL POWER WAIT FOR HEATER TO COOL BEFORE CLEANING Follow Safe...

Page 19: ...TD CTL DT 24V DSI NAT HA 16550451 ASY XTD CTL DT 24 V DSI B P 16550452 ASY XTD CTL DT 24V DSI B P HA 16550086 SPACER BURNER INNER CONE SHORT 2 each 16550038 HEAT DEFLECTOR LEFT 2 each 16550037 HEAT DEFLECTOR RIGHT 2 each 16550015 CANOPY 1 each 16550081 CENTER SUPPORT CANOPY 1 each 16550080 END PLATE CONTROL END 1 each 16550079 END PLATE OPPOSITE CONTROL END 1 each 165050126 IGNITION CONTROL BOX TO...

Page 20: ...50085 PAN CHANNEL REFLECTOR 2 each 16550089 CORRUGATED INNER CONE 1 each 16550082 BOTTOM FLAME SHIELD 1 each 16550084 EMITTER PANEL 12 each 16050048 INSULATION END PANEL 2 each 16050046 INSULATION BOTTOM PANE 1 each 16050047 INSULATION SIDE PANEL 2 each 16550093 BURNER ASSEMBLY 1 each ...

Page 21: ...N WIRE HARNESS KIT 24V 16550325 VALVE ASSY 24V W BRKT STRAIN RELIEF 1each 16550436 PLASTIC BOX SHIELD 1 each 16 13109150 HOG RING 2 each 2 each 16 11194 BUSHING GALVD STD HEX X 1 each 11000058 ADAPTER 3 8 MPT X 3 8 MF 1 EACH 10106615 HEYCO STRAIN RELIEF SR7K 2 1 each 16550473 WIRES ASSY LoPRESS WSHBX 1650158 ORIFICE 37 LP 16050160 ORFICE 39 LP HA 16050159 ORIFICE 38 B P 16050161 ORIFICE 41 B P HA ...

Page 22: ...3 ASY CTL XTD WDP 24 V DSI B P 16550464 ASY CTL XTD WDP 24V DSI B P HA 16000047 RUBBER BOOT FOR TOGGLE SWITCH 1 each 13008107 STRAIN RELIEF 1 each 16550223 HANG TAG WITH CLEANING LABLE 1 each PARTS NOT SHOWN IN ILLUSTRATION 16050021 RIVET POP 3 16 SS SSD 26 13005235 TECK SCREW 8 X 4 16000149 SCREW 8 32 X HWS TYPE 23 4 16 27020750 SCREW TYPE F HWS 8 32 X 2 16550301 HANG TAG WASH DOWN INSTRUCTIONS 1...

Page 23: ...s or more information see our website at www ctbinc com 23 16050208 DRIP LEG 1 13005255 PIPE TEE X X 1 1 2 13004937 VALVE BRASS VALL 1 3 13005228 PIPE NPL CLOSE BLK 2 4 13005193 PIPE NPL X 3 BLK 1 5 13005229 PIPE CAP BLK 1 ...

Page 24: ...For additional manuals or more information see our website at www ctbinc com 24 ...

Reviews: