57" Assembled & Unassembled Direct Drive Endura® Fan
Test Fan for proper operation
23
Supply power to the VFD and check for proper operation. If the Fan turns in the wrong direction interchange any
two wire connections between the drive and the motor to correct the direction of fan blade rotation.
IMPORTANT!
Disconnect Power Prior To Maintaining Or Cleaning The Fan. The fan may start automatically
causing serious injury or death.
•
Service and repair of fans should be done only by a qualified technician.
•
Minimize contact of moisture or corrosive chemicals to the surfaces of the fan components to maximize fan
life.
•
After washing fans, operate fans long enough to remove moisture from all fan surfaces.
•
Keep the fan clean for maximum life and best performance.
Test Fan for proper operation
Maintenance