Watering Regulator for Cage Systems
4
MW1642D
Regulator Operation
Recommended incoming water pressure to
the regulator assembly: 30 to 35 psi
max
[207 to 241 kPa max]
.
Adjust water column by turning the knob on
the bottom of the regulator,
STOP turning the
adjustment knob as soon as
resistance is noticed or damage will
occur.
Water column adjustment knob for PDS™
regulators is used to set a
default
water
column. This
default
will be the
operating
water column in the event of an air pressure
loss to the PDS system.
Set the
default
water column with consideration of the bird age. Lower
default
water column should be used for
young birds so the nipple valves do not become hard to operate.
PDS Controllers
CAN NOT
adjust the
operating
water column below the set
default
water column.
Functional Modes:
There are three (3) selectable modes for operating the water regulator (OFF, REGULATE, and FLUSH). These
modes are selected by using the individual regulate and flush control knobs.
•PDS™ controlled regulators are to operate in the
REGULATE
mode.
•Flushing the system does not require turning off the regulate control knob.
DO NOT FLUSH DRINKER LINES WITH PDS™ CONTROL unless drinker lines are
pressurized with water! Product damage may occur if this caution is not followed.
•When flushing the system make sure the outlet line is clear of restrictions. Excessive back pressure can
damage the regulator.
Setting Functional Modes:
1.Rotate the control knob to free the latch.
2.Pull up on the control knob.
Control knobs: UP position is ON and DOWN position is OFF.
3.Always lock the control knob into position by rotating knobs
into the shown positions,
Water Column
Adjustment
FLUSH
Control Knob
REGULATE
Control Knob
Water Outlet
Water Inlet
Figure 6. Water Regulator
FLUSH
OFF
REGULATE
Figure 7. Functional Mode Settings