OPERATION 

  

When the amplifier is connected to the mains the central clear ball will illuminate red (standby).  Press the ball in to 

switch on the amplifier. The ball will illuminate green (operational). There will be a delay of about 12 seconds before 

the output signal is fed to the loudspeakers the ball will then change to blue to indicate the output relays are engaged.  

In the event of a major overload or a short circuit across the output of any channel, the blue "power on" illumination 

will indicate trip by fading and immediately re-illuminating to red standby mode.  The amplifier will shut down 

automatically and it should then be switched off at the mains outlet.  When the fault condition has been rectified, the 

amplifier can be switched on and will power up as normal.  A minimum period of 1 minute must be allowed to elapse 

between switching off and switching on again.  This is to allow the power supply protection circuitry to re-set itself.  

This amplifier is fitted with a trigger system designed to switch the unit on or off remotely. 

N.B. with no plug inserted in the 12V trigger socket, the amplifier will operate as normal. 

The external trigger should be connected to the amplifier via a standard 1/8

th

 inch / 3.5mm (mono or stereo) jack plug 

to the socket fitted to the rear of the unit.  

The amplifier should be switched into the standby position (red illumination) and the 12V trigger lead inserted. The 

amplifier will now switch on when the trigger voltage is applied, and will switch off again when the voltage is 

removed (Positive Trigger). The front panel ball will indicate orange when the trigger is connected and change to 

purple when the trigger is operating to switch on the amplifier.  You do not need to switch on the amplifier by pressing 

the ball on the front panel when the trigger is used – however it will still operate normally if you use the front panel 

button. 

The connections are as follows: 

  

 

The tip of the plug is the +5V to +12V dc connection, the centre and rear connection are the 0V or ground connection.  

CARE AND CLEANING

  

The SPM 6000 Mk2 requires no special care other than common-sense.  Spray window cleaner (clear type) may be 

used (if first sprayed on to a soft cloth) to remove surface blemishes such as finger marks from the metal casing or the 

wooden side cheeks (if fitted).  Never spray directly on to the amplifier and never use abrasive cleaning materials, use 

only a lint free soft cloth as described. 

SERVICE INFORMATION 

There are no user serviceable parts in your SPM 6000 Mk2.  It should only be serviced by Chord Electronics Limited 

or their expressly approved Service Agents.  

WARNING

 - The power supply components within this amplifier are designed to be operated at lethal voltages and 

energy levels.  Circuit designs that embody these components conform to applicable safety requirements.  Precautions 

must be taken to prevent accidental contact with power-line potentials.  Do not connect grounded test equipment. 

+5V to +12V dc.

0V / Ground