background image

 

- 11 - 

 

 

 

Function instruction of DHCP CLIENT

 

Function 

Description 

Host Name (optional) 

Fill in the host name , default setting is 

CHIYU

 (optional)

 

Serial Port Mode

 

Serial Type 

Set the serial type, RS232 and RS485 for setting , default setting is 

RS232

 

Baud Rate 

1.Set serial port baud rate, the parameters can be selected

1200

2400

4800

9600

19200

38400

57600

115200

230400 and 

Others

 

2.After selecting 

Others

 , fill custom baud rate into the user defined 

3.Default setting is 

19200

 

Operation Mode

 

Connection Mode 

There are

 4 modes

 to set into connection mode, such as

 

 

TCP Server 

 

TCP Client 

 

UDP Server

 

 

UDP Client

 

Connection Port Number 

Set 

BF-430

 connection port number, default setting is 

50000

 

Remote Host IP Address 

(For Client Only) 

1.Set the remote host IP address, the default setting is

 0.0.0.0

 

2.

For Client Only 

Summary of Contents for BF-430

Page 1: ...BF 430 User Manual Document Version 1 0 Web Version realcom 2009 02 07 Firmware Version 1 13 00 Apr 4 2011 ...

Page 2: ... Server 13 2 TCP Client 14 3 UDP Server 15 4 UDP Client 16 2 Serial Port Setup 17 3 DDNS Setup 18 1 TZ0 18 2 Dyndns 19 Management 20 1 Device Administration Setting 20 2 System Status Monitor 21 3 Backup Restore Configuration 22 4 Firmware Upgrade 23 5 PING 24 Copyright 2011 All Rights Reserved All trademarks and trade names are the properties of their respective owners ...

Page 3: ...2 Signal 4 wire R R T T only for BF 430 CPU 16 bit CPU 100MHz Memory 256K ROM 768K SDRAM Watch Dog System never halts I O Support No LED 4 Power RXD TXD ACT Power Requirement DC 9 30V 300 mA Power Requirement 300mA 9V EMI EMC Certification FCC B CE B System Requirement Operation temperature 0 65 Storage temperature 20 85 Operation humidity 5 95 Surge Protection Serial port 15 KV ESD Magnetic Prote...

Page 4: ... 2 End point ...

Page 5: ...TCP server client 及 UDP server client Users can select suitable connecting way Support DHCP Client when activate this function BF 430 can get TCP IP default from DHCP Server when the system activates Includes IP address default getaway IP and DNS server Support PPPoE PPPoE is an internet protocol for the link simulation of dial up connection and remote host Support Dynamic DNS this enable BF 430 c...

Page 6: ...with power supplied If the default IP address 192 168 168 125 is occupied by else device then it is a must to shut down that device first till the setting is over and then allocate new IP address to BF 430 How to search BF 430 1 After installation of BF 430 and network cable is completed use BF 430 s IP Search to search all BF 430 in a certain LAN or download IP Search tool from CHIYU homepage Des...

Page 7: ...ac Address Select particular BF 430 then its related information will appear below the window as shown 4 The showed information of BF 430 can be revised directly in the window the part can be modified IP Address Subnet Mask Gateway After modification completed MAC Address can not modify click Alter then it will display the modified information as shown ...

Page 8: ...430 has two methods 1 Open IP Search select and double click particular BF 430 then to enter its webpage 2 While the internet explorer opened input BF 430 IP address to enter its webpage Remark WINDOWS XP Step 1 Click WINDOWS XP my computer Open Control Pan on the left side please turn to traditional overview and select network link Step 2 Click LAN then select content the link configuration will ...

Page 9: ...on select open and search for click Alter Interface Card on the upper left side Step 2 Click LAN link select content then the LAN settings will be shown click Internet Protocol TCP IPv4 then input the same setting as BF 430 as below figure ...

Page 10: ... 430 connection input command ping 192 168 168 125 as shown below If no response received it explains the link has troubles either the connection is not proper or the PC s IP address can not match with BF 430 s IP address Set the PC s IP address with BF 430 s IP address with same segment if the PC uses fixed IP address the address must be ranged in 192 168 168 1 192 168 168 65 or 192 168 168 67 19...

Page 11: ...splay a message window for User name and Password the default for user name and Password is admin admin as shown below 4 While the user name and password entered a Web setting interface of BF 430 will be showed enter it will then display a One Page Quick Setup page ...

Page 12: ...e Set the serial type RS232 and RS485 for setting default setting is RS232 Baud Rate 1 Set serial port baud rate the parameters can be selected 1200 2400 4800 9600 19200 38400 57600 115200 230400 and Others 2 After selecting Others fill custom baud rate into the user defined 3 Default setting is 19200 Operation Mode Connection Mode There are 4 modes to set into connection mode such as TCP Server T...

Page 13: ...selected 1200 2400 4800 9600 19200 38400 57600 115200 230400 and Others 2 After selecting Others fill custom baud rate into the user defined 3 Default setting is 19200 Operation Mode Connection Mode There are 4 modes to set into connection mode such as TCP Server TCP Client UDP Server UDP Client Connection Port Number Set BF 430 connection port number default setting is 50000 Remote Host IP Addres...

Page 14: ... fill in fixed IP Default setting is DISABLE optional Serial Port Mode Serial Type Set the serial type RS232 and RS485 for setting default setting is RS232 Baud Rate 1 Set serial port baud rate the parameters can be selected 1200 2400 4800 9600 19200 38400 57600 115200 230400 and Others 2 After selecting Others fill custom baud rate into the user defined 3 Default setting is 19200 Operation Mode C...

Page 15: ...ect with monitoring side or the connection will be off automatically when remote idle Access Password Make sure the data secure user must set the code for management User must inset the correct password and process the further procedure after authority up to 31 characters Keep Alive Check Set Enable or Disable keep alive check function default setting is Disable While keep alive check enable the p...

Page 16: ... 0 TCP Connection There are 2 modes to set TCP connection to server 1 Start Up This mode means when BF 430 enable it will build the TCP connection with SERVER immediately It will automatically build the TCP connection after disable and then re connect again 2 Any Character This mode means only when BF 430 receives data from RS232 485 it will build TCP connection with SERVER TCP connection will be ...

Page 17: ...uction Function Description Local Listen Port Number If data transmit thru UDP remote command must select Serial Server Mode into UDP SERVER and set LISTEN PORT NUMBER into the same value with monitoring side Default setting is 50000 ...

Page 18: ...struction Function Description Remote Connection Port Number Set the remote connection port number the range is 0 65535 default setting is 50000 Remote Host IP Address Set the remote host IP address the default setting is 0 0 0 0 ...

Page 19: ...control CTS RTS Hardware flow control Default setting is None Force Packet Transmit Time ms Force packet transmit time The minimum setting is 0 ms of setting serial interval between data Default setting is 0 the range is 0 65535ms Force Packet Transmit Length bytes Force packet transmit length The serial set length of data transmission range is from 0 65535 bytes the default setting is 0 Delimiter...

Page 20: ... key Fill in the password key for DDNS up to 31 characters Device DNS Name Fill in the device DNS name for example hostname tzo com Registry IP Address Display the registry IP address when DDNS is enabled It will show the registry IP address Status Display DNS Serve status when DDNS server does not enable it will show DDNS function is disabled ...

Page 21: ... the password for DDNS up to 31 characters Device DNS Name Fill in the device DNS name for example hostname dyndns org Registry IP Address Display the registry IP address when DDNS is enabled It will show the registry IP address Status Display DNS Serve status when DDNS server does not enable it will show DDNS function is disabled ...

Page 22: ...name default setting is CHIYU Device Location Fill in the device location default setting is blank Administrator Password User Name Fill in the user name Password Change Change the password for security reasons please fill in a new password to replace the default management Password Confirm Confirm the new password Block Ping Request Select unblock or block ping request function default setting is...

Page 23: ...68 125 Subnet mask Display BF 430 Subnet mask default setting is 255 255 255 0 Default Gateway Display BF 430 Default Gateway default setting is 192 168 168 254 Primary DNS Display BF 430 Primary DNS address default setting is 168 95 1 1 STATUS Display BF 430 internet status Serial Status Serial Type Display Serial type default setting is RS232 Baud Rate Display Baud Rate default setting is 19200 ...

Page 24: ...uction Function Description Backup After execution can save the present system settings as a backup file and save it in hardware the sub name of the saved file is cfg Restore Browse and select saved file cfg execute Restore to restore system settings ...

Page 25: ...file to upgrade Browse and select firmware execute Upgrade to upgrade firmware Has to assure the possibility of power supply during the process of upgrading or severe damage will be caused What if upgrade different firmware to different products and it will also cause severe damage ...

Page 26: ...F 430 IP address Destination IP Address Input IP address of Remote Host Packet Number Set up the number of PING package ranged 1 4 the default 4 Ping Size Set up the size of PING package the utmost setting 1460 bytes Ping Result Display Sent Request data Display Receive Reply data ...