BCD-430WP Service Manual
21
(2)
The operating state can be adjusted by pressing the ‘Temp.’ key.
Parameter Items
Operating parameter values (0 indicates OFF,
and 1 indicates ON) and temperatures
Original value
Parameter set value
C1
Fridge temperature
d1
Freezer temperature
d2
Freezer evaporator temperature
CH
Ambient sensor temperature
C
(
compressor
)
0
0
,
1
Fc
(
fridge air damper
)
0
0
,
1
Fd
(
freezer fan
)
0
0
,
1
Hc
(
fridge damper
heater
)
0
0
,
1
HD (freezer heater)
0
0
,
1
HL (anti-condensation
heater)
0
0
,
1
(3)
During the running of the maintenance program, the compressor keeps
rotating at 3000rpm.
(4)
After the operating state is set, the refrigerator will run according to the
maintenance program.
(5)
During the running of the maintenance program, you can press the ‘Temp.’
key to change the load running state at any time, or to view the real-time
value of each sensor.
(6)
Exit conditions
The maintenance program keeps running for at most 3 hours, beyond
which it will automatically exit, with the normal operation program
restored.
When the refrigerator is powered off and then on again, the
maintenance programgets exited immediately.
5.
Disassembly instructions for key components
How to disassemble the fridge air duct assembly.