![ChimneyFree 18WM20124 User Manual Download Page 35](http://html1.mh-extra.com/html/chimneyfree/18wm20124/18wm20124_user-manual_2601770035.webp)
www.tsicustomerservice.com
A153R1
7
2. Carefully tilt front frame assembly forward a couple
of inches. Then lift complete glass assembly up and
away from unit (Fig. 2).
1. Turn the master power switch off, then unplug
the power cord from the wall outlet.
If fireplace has been operating, let the unit cool
at least one hour.
Locate and rotate the 2 screws on the front frame
assembly in counterclockwise direction to loosen
the front frame assembly from insert. (Fig. 1).
3. Locate the two ember bed securing nuts on the left
and right sides of the log set. These securing nuts
are disguised as wooden embers (Fig. 3).
4. Turn nuts counterclockwise to loosen, remove and set
aside. Securely grab logs on left and right side and lift
log/ember bed assembly straight up. Once ember bed
has cleared the support bracket and threaded rods,
bring log/ember bed assembly forward and out of unit
and set aside in a safe place (Fig. 4).
Wooden
Ember Nut
Logs/Ember bed
Ember bed Mounting Post
4
5. Unhook light bulb spring clips from the bulbs, and
unscrew the bulbs (Fig. 5) After replacing the
bulbs make sure to replace the light bulb spring
clip.
Follow steps 1 through 4 in reverse order to
reinstall front frame assembly into your insert.
Ember bed Light Bulb
Light Bulb Holding Spring
Pull
Pull
5
CLEARANCE TO COMBUSTIBLES
Keep electrical cords, drapery, furniture and other combustibles at least 3 ft. from the front of the heater and away
from the sides.
CLEANING TRIM
Clean the metal trim using a soft cloth, slightly dampened with a citrus oil-based product and buff with a clean soft
cloth. Do not use brass polish or household cleaners as these products will damage the metal trim. Citrus oil-based
products can be obtained at supermarkets or hardware stores.
• The motors used on the fan and the flame generator assembly are pre-lubricated for extended bearing life and
require no further lubrication. However, we recommend periodic cleaning/vacuuming of the fan/heater.
• Make sure the unit is turned off and unplugged whenever you are cleaning the heater or fireplace.
Summary of Contents for 18WM20124
Page 4: ...MP HCH 4 www tsicustomerservice com 18WM20124REV 1 K L N H O M P J Q I E F D G B C A 18WM20124...
Page 7: ...MP HCH 7 www tsicustomerservice com 18WM20124REV 1 N C B D EE CC x4 x8 1...
Page 8: ...MP HCH 8 www tsicustomerservice com 18WM20124REV 1 2 AA x8...
Page 9: ...MP HCH 9 www tsicustomerservice com 18WM20124REV 1 E L M F 3 CC x6 BB x8...
Page 10: ...MP HCH 10 www tsicustomerservice com 18WM20124REV 1 4 A AA x6...
Page 11: ...MP HCH 11 www tsicustomerservice com 18WM20124REV 1 A 5 CC x12 DD x6...
Page 12: ...MP HCH 12 www tsicustomerservice com 18WM20124REV 1 6 BB x6...
Page 13: ...MP HCH 13 www tsicustomerservice com 18WM20124REV 1 x8 7 H AA...
Page 14: ...MP HCH 14 www tsicustomerservice com 18WM20124REV 1 H 8 CC x6 BB x8...
Page 15: ...MP HCH 15 www tsicustomerservice com 18WM20124REV 1 x2 AA 9 P O...
Page 16: ...MP HCH 16 www tsicustomerservice com 18WM20124REV 1 CC x2 BB x4 10 I P J O...
Page 17: ...MP HCH 17 www tsicustomerservice com 18WM20124REV 1 x6 AA 11...
Page 18: ...MP HCH 18 www tsicustomerservice com 18WM20124REV 1 CC x4 12 Q...
Page 19: ...MP HCH 19 www tsicustomerservice com 18WM20124REV 1 CC x6 BB x6 13...
Page 20: ...MP HCH 20 www tsicustomerservice com 18WM20124REV 1 x9 AA 14 G...
Page 21: ...MP HCH 21 www tsicustomerservice com 18WM20124REV 1 G 15 CC x8 BB x9...
Page 22: ...MP HCH 22 www tsicustomerservice com 18WM20124REV 1 K 16 EE x12...
Page 24: ...MP HCH 24 www tsicustomerservice com 18WM20124REV 1 17...
Page 25: ...MP HCH 25 www tsicustomerservice com 18WM20124REV 1 18...
Page 30: ...www tsicustomerservice com A153R1 2...
Page 39: ...www tsicustomerservice com A153R1 11 www tsicustomerservice com...