TROUBLE SHOOTING 

Problem

Root Cause

Corrective Action

No power

Power cord was not 

plugged into the outlet.

Check that the unit is plugged into a standard 120V outlet.

Logs Glow, flame effect 

does not work.

Spinner Motor.

Check whether Flame Generator drive motor is running . If not call the 

customer service.

Flame effect operates, but 

heater does not 

blow warm air.

Heater is not on 

position.

Try to turn ON/OFF  HEATER button several times to make sure it is in ON 

position.

Temperature is set at low.

Make sure that the TEMPERATURE knob is set to the max setting.

The heater shut off and 

won't come back on.

Manual Reset Triggered

Turn the POWER to “OFF” and unplug the unit from the wall outlet for 5 

minutes. After 5 minutes plug the unit back into wall outlet, and operate as 

normal. If the problem presist contact customer service.

Power cord gets warm.

Normal operation 

Check your heater cord and plug connections. Faulty wall outlet connections or 

loose plugs can cause the outlet or plug to overheat. Be sure the plug fits tight in 

the outlet. Heaters draw more current than small appliances, overheating of the 

outlet may occur even if it has not occurred with the use of other appliances. 

During use check frequently to determine if your plug outlet or faceplate 

is HOT! If so, discontinue use of the heater and have a qualified 

electrician check and/or replace the faulty outlet(s).

No flames sound,  but have 

flames effect.

Sound button turned off

Press Sound button several times.

Loose terminal blocks or  

damaged loudspeaker

Must be replaced by the manufacturer, contact customer service for a 

replacment. 

Remote Control is not 

working.

No batteries

Change the remote batteries.

Poor Signal

Operate remote transmitter at a slow measured pace. 

Press the remote control buttons with an even motion  and gentle pressure. 

Repeatedly pressing buttons in rapid succession may cause the transmitter to 

malfunction.

Distance

Operate the remote at a distance less than 20 feet from the front of the 

appliance; point the remote at the control panel.

Unit continues to run after 

reaching set temperature/or 

powering off.

Cool down cycle

Normal operation, will continue to run for several minutes before shutting 

down.  Times will vary based on heating. UNIT WILL BLOW COOL AIR.

Flame effect works but 

heater function does not 

and the emberbed flashes 

when the heater button is 

pressed. 

The heater is disabled.

With the power on and press and hold the heater button on the control panel 

for 10 seconds. Once re-enabled the emberbed lights will flash multiple times.

Summary of Contents for CFI040ARU-05

Page 1: ...www tsicustomerservice com A614 1 www tsicustomerservice com Twin Star International Inc Delray Beach FL 33445 Made in China Printed in China 1 866 661 1218 MODEL CFI040ARU 05 TM MC MR...

Page 2: ...lete registration save your proof of purchase for warranty purposes PRODUCT SPECIFICATIONS VOLTAGE 120VAC 60 Hz AMPS 12 5 Amps WATTS 1500 Watts 1 866 661 1218 www tsicustomerservice com SN AB XXXXX X...

Page 3: ...or the like Arrange cord away from traffic areas and where it will not be tripped over 11 To disconnect this appliance turn controls to the off position then remove plug from outlet 12 This product i...

Page 4: ...614 4 OPERATION INSTRUCTIONS The fireplace can be operated by either the remote control or the control panel EMBERBED UNDULATION FLAME POWER HEATER Control Panel THERMOSTAT HEATER FLAME FLAME SOUND Fl...

Page 5: ...e selected The HEATER button will turn ON OFF the heater THERMOSTAT The thermostat knob controls the thermostat setting Turning the knob clockwise will increase thermostat setting Rotating the knob co...

Page 6: ...with the use of other appliances During use check frequently to determine if your plug outlet or faceplate is HOT If so discontinue use of the heater and have a qualified electrician check and or rep...

Page 7: ...polish or household cleaners as these products will damage the metal trim Citrus oil based products can be obtained at supermarkets or hardware stores WARNING Electrical outlet wiring must comply with...

Page 8: ...ct the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15...

Page 9: ...lity for same 6 The owner user assumes all other risks if any including the risk of any direct indirect or consequential loss or damage arising out of the use or inability to use the product except as...

Page 10: ...www tsicustomerservice com A614 10 www tsicustomerservice com TM MC MR...

Reviews: