  4

 

 

 

 

1

 

製品使用上のご注意

Cautions on Using Product

 

1.1 

全般 

General

 

 

設置、接続、運転、操作、点検、故障診断の作業は、取扱説明書の内容に従い、適切に行って下さい。

 

誤った作業を行うと、火災・感電・けがの原因になります。

 

Perform installation, connection, operation, manipulation, inspection and failure diagnosis work properly in 
accordance with the instruction manual. Incorrect work may cause fire, electrical shock and injury. 

1.2 

運搬・設置・保管・輸送の条件 

 

The condition of carry installation, transportation and safekeeping 

 

 

輸送・保管については安全な場所で、温度

-10

℃~

60

℃  湿度

80%

以下の範囲として下さい。

 

For  transport  and storage,  keep in a safe  place,  with  a  temperature  range  of  -10  to +60

  and  humidity 

below 80%. 

 

運搬や設置は、二人以上で行って下さい。落下などにより、けがをする恐れがあります。

 

During  carrying-in  and  installation,  enlist  the  help  of  others  when  carrying  heavy  objects  to  prevent  an 
accident. There is danger of injury due to falling. 

 

回転機器が内蔵されていますので、水平で振動の無い場所に設置して下さい。

 

Rotary equipment is built into the product. Install the product in a horizontal place without vibrations. 

 

爆発・引火性ガス・腐食の危険がある場所や、水のかかる場所、可燃物のそばでは使用しないで下さい。

 

Do not use the product in places with explosive or flammable gas, with corrosion risk, with water splashes 
or near combustible substances. 

 

本機は、屋内クリーンルーム内  又は、清浄度の高い工場に設置することを前提とした構造となっていますので、屋
外などには設置しないで下さい。

 

The product is designed to be installed in an indoor clean room or highly cleaned factory. Do not install it 
outdoors. 

 

常温(周囲温度

0

40

℃ 

/

  湿度

80

%以下)で、結露しない場所に設置して下さい。高温・結露は、電気部品の故

障、感電の原因になります。

 

Install  the  product  in  a  place without  dew  condensation  at  room  temperature  (ambient  temperature:  0  to 
40ºC,  humidity: 80%  or  less). High temperature  and  dew  condensation  may cause  electrical  parts  to  fail 
and may cause an electrical shock. 

 

排気口は十分なスペース(排気口より

100

㎜以上)を設けて下さい。排気口を塞ぐと正規の吸引力が発揮できませ

ん。また、ボックス内部で十分な冷却が行われないため、モータ焼けや電気部品の故障原因となります。

 

Provide sufficient space around the exhaust port (100 mm or more). 
Clogging the exhaust port disables the regular suction force, and may cause motor burning and electrical 
part failure due to insufficient cooling inside the product. 

 

フィルタの交換、メンテナンスのしやすい場所に設置して下さい。

 

(フィルタ交換のため、本体正面から

350

㎜以上のスペースが必要です。)

 

Install the product in a place where filter replacement and maintenance can be performed easily. 
(To replace filters, a space of 350 mm or more is required from the main body front face.) 

 

本機は歩行面から

0.2

2

mの範囲で設置してください。

 

Install the product in a place 0.2 to 2.0 m from the walking surface. 

 

本機の設置標高は

1,000

m以下です。

 

The installation height of the product is 1,000 m or less 

 

設置区分は汚染度Ⅱ

(

製造工場

)

です。

 

The installation classification is “Contamination level 

  (manufacturing plant).

 

1.3 

接続 

Connection

 

 

接続は、確実におこなって下さい。ケーブルを無理に曲げたり、引っ張ったりしないで下さい。

 

火災・感電の原因になります。

 

Connect the product securely. 
Do not bend or pull cables forcibly. Forcible bending or pulling may cause a fire and electrical shock. 

 

異なった電源で使用しないで下さい。また、アース線を接続してお使い下さい。

 

Use the correct power supply, and connect the ground wire. 

 

電源の過電圧カテゴリーは区分Ⅲです。(産業用装置など)

 

The category of over-voltage of the power supply is division 

  (industrial device). 

Summary of Contents for CBA-080AT-HC

Page 1: ...lead to a serious accident caused by incorrect handling CAUTION This symbol indicates cautions to assure safe use and actions that may lead to failure caused by incorrect handling Instruction Manual M...

Page 2: ...osene paint etc Explosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire sources Cigar...

Page 3: ...onfirmation before operation 9 4 5 Operation procedure 10 5 Remote Cable Sold Separately 11 5 1 Electrical circuit diagram 11 5 2 Remote Cable 11 5 3 Color and signal of each wire 12 5 4 Remote operat...

Page 4: ...t outdoors 0 40 80 Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electri...

Page 5: ...pair 1 6 Disposal Dispose of the product properly as industrial wast 2 Confirmation and Preparation at Arrival After unpacking make sure that all parts are provided Contact our company immediately if...

Page 6: ...rimary filter Collecting Adsorbing fine dust and fumes Secondary filter Protecting the circuit and the electrical parts Exhaust filter Exhaust treatment 3 Power cable 3m Exhaust port AT AT Panel opera...

Page 7: ...z CBA 1200AT HC V1 CE 200V 240V 50 60Hz CBA 2000AT HC V1 200V 50 60Hz 10 3m The allowable supply voltage range is 10 The power cable of 3 m with a grounding plug is included 4 2 AT AT panel Filter sat...

Page 8: ...o Push here to lower gradually suction speed Minimum Lo 40 power Hi 1 1 100 Hi Push here to increase gradually suction speed Maximum Hi 100 power ON OFF ON OFF switch and Main Power supply Light up Re...

Page 9: ...grounding plug are connected correctly insulation is provided properly and the rated voltage is realized Confirm the items 1 to 3 above and then proceed to the item 4 AT Turn ON the MAIN POWER switch...

Page 10: ...to a proper position Turn ON the MAIN POWER switch and confirm that the power indicator lamp lights Starts the dust collector AT ON Press the ON switch to start the operation 7 Choose operation abili...

Page 11: ...s put inside a shrinkable tube so that it cannot be short circuited with other wires Remote operation switch ON Shifting to remote mode Remote control is possible in the ON and the panel is impossible...

Page 12: ...panel is disabled while the wires 4 and 8 are short circuited Yellow white Black White Operation pressure signal Output signals Transfers the current operation output Analog signal 1 5V Impedance 4 7...

Page 13: ...in body Transfer required output signals in accordance with the explanation in 5 3 Color and signal of each wire AT ON Lo Hi Change with Lo Hi switch pushing the ON switch of main body AT panel when y...

Page 14: ...filter grid frame should be located on the exhaust side Make sure to turn OFF the main power and disconnect the power plug from the electrical outlet to cut off the electricity before starting inspec...

Page 15: ...s into the clearance on the left and right sides between the filter case and the filter to remove the filter easily Remove the primary filter from the filter case The paper packing of the primary filt...

Page 16: ...g operation Does the suction hose end offer proper suction force Is the clogging indicator lamp extinguished When the fuse is blown out by excessive current generated by a trouble in the internal equi...

Page 17: ...ing 1 to 3 above remove the cause of error and press the RESET switch Or turn OFF and ON the MAIN POWER switch to reset the error status Start the operation 30 minutes later Fuses are blown out 6 5 Re...

Page 18: ...IRTEC CO LTD 2009 18 8 Indication of DANGER Labels P r o h i b i t i o n l a b e l P r o h i b i t i o n o f d i s a s s e m b l y W a r n i n g l a b e l H i g h v o l t a g e P r o d u c t n a m e p...

Page 19: ...Copyright CHIKO AIRTEC CO LTD 2009 19 9 Electrical Circuit Diagram CBA 080AT HC 100V CBA 080AT HC CE 200 240V...

Page 20: ...Copyright CHIKO AIRTEC CO LTD 2009 20 CBA 1200AT HC CE CBA 500AT HC CE...

Page 21: ...s CBA 080AT HC V1 250 100 110 Single phase 4 5 50 60 1 5 8 5 54 67 10 0 CBA 080AT HC V1 CE 400 200 240 Single phase 3 0 50 60 1 5 7 8 8 9 200V 240V 54 67 14 5 CBA 500AT HC V1 450 100 110 Single phase...

Page 22: ...2525 50 V1 CBA 500AT HC V1 FB 30 CHF 3030 50 CHF 3030 50 HEP 3030 69 V1 CBA 500AT HC V1 CE FB 30 CHF 3030 50 CHF 3030 50 HEP 3030 69 V1 CBA 1200AT HC V1 FB 30 CHF 3030 50 CHF 3030 50 HEP 3030 69 V1 CH...

Page 23: ...emo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 2 27 24 2 27 24 Hakushima Minoh City Osaka apan 562 0012...

Reviews: