![Chigo CS-25V3A-MA114A Service Manual Download Page 38](http://html1.mh-extra.com/html/chigo/cs-25v3a-ma114a/cs-25v3a-ma114a_service-manual_2601250038.webp)
38
The refrigerant leaked
completely
refill up refrigerant after
checking the
leak source
.
The system blocked completely
Check capillary tube,strainer
etc. repair or replace them.
other
03
Not heating well.
The room is too large ;the
window or door is not closed.
Close the window and door
The set temperature is too low.
Heighten
the set temperature.
The air filter is dirty.
Clean this filter.
The refrigerant leaked.
refill up refrigerant after
checking the
leak source
.
The system blocked slightly
Check capillary tube, strainer
etc. repair or replace them.
The outdoor temperature is too
low.
The A/C can
’
t melt down frost
or
Replace this sensor or move
the sensor to the thickest
position of frost
The indoor or outdoor motor
speed is lower
Replace this fan motor
The compressor suction or
venting capability is very poor
Replace this compressor
Four-way valve slight mixes up Let the four-way valve moving
continually. Replace the
four-way valve if it can’t move
The capillary valve has been
blocked.
Replace this capillary valve
other
04
Can not heating.
The fan doesn’t run (motor or
capacitor of fan failed, Poor
contact for the line of capacitor,
line or PCB fault
.).
Check. Repair and replace.
The compressor doesn’t
work(the voltage is too low or
high, overload,
wiring error
. The
compressor failed. The
capacitor of compressor
failed.the capacity of
electric
fence
isn’t enough. )
Check. Repair and replace.
The refrigerant leaked.
refill up refrigerant after
checking the
leak source
.
The system blocked completely
Check capillary tube,strainer
etc. repair or replace them.
The compressor failed.
Replace compressor.
The compressor is blocked
replace it
The four-way valve failed and
can’t replace direction.
Check the circuit and replace
the four-way valve.
Summary of Contents for CS-25V3A-MA114A
Page 3: ...3 A Summary 1 indoor unit 2 outdoor unit 3 remote controller...
Page 4: ...4 B Wiring diagram Wiring diagram INDOOR CS 25V3A MA114A CS 35V3A MA114A...
Page 5: ...5 Wiring diagram OUTDOOR CS 25V3A Y4N CS 35V3A Y4P...
Page 18: ...18 2 Outdoor CS 25V3A Y4N CS 35V3A Y4P...
Page 42: ...42 I User s Manual...
Page 43: ...43 The name of each part and its function...
Page 44: ...44 Remote controller...
Page 45: ...45 Use of remote controller Operating machine in selected modes...
Page 46: ...46...
Page 47: ...47 Basic principles and performances Features of Heating Operations Methods of maintenance...
Page 48: ...48...
Page 49: ...49...
Page 50: ...50...