New CMV System - 4-Way Cassette Indoor Unit
7.2
Dial switches
7.2.1
SW1: Capacity switch.
Different number in the switch indicates different capacity. It is set in factory; leave it as default setting,
HP
0.8
1
1.2
1.7
2
2.5
Capacity (kW)
1.8/2.2
2.5/2.6/2.8
3.2/3.5/3.6
4.0/4.5/4.6
5.1/5.6
6.0/6.6/7.1
Code
0
1
2
3
4
5
HP
3
3.2
4
5
6
Capacity (kW)
8.0
8.8/9.0
10.0/11.0/11.2
12.0/12.5/14.0
15.0/16.0
Code
6
7
8
9
9
7.2.2
SW3
Name
Switch number 1 of SW3
Switch number 4 of SW3
Switch number 2,3 of SW3
Function
Auto-restart when power failure switch.
ON/OFF status, operation mode, fan
speed, temperature, swing, remote
control locked will be recovered.
Indoor unit address elimination
Reserved
Setting
ON
DP
1 2 3 4
Dial up to disable Auto-restart function
ON
DP
1 2 3 4
ON
DP
1 2 3 4
Dial up to erase indoor unit’s address.
ON
DP
1 2 3 4
ON
DP
1 2 3 4
Default setting
ON
DP
1 2 3 4
Dial down to enable Auto-restart
function (Default setting)
ON
DP
1 2 3 4
ON
DP
1 2 3 4
Default setting