![Chigo CCA-18HVR1 Technical Manual Download Page 57](http://html1.mh-extra.com/html/chigo/cca-18hvr1/cca-18hvr1_technical-manual_2601243057.webp)
R410A50Hz Universal Outdoor Series Technical Manual
54
GUANGDONG CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
6.
Capacity Tables
Cooling
6.1 CTA-18HVR1
MODEL
CTA-18HVR1
COOLING
OUTDOOR TEMPERATURE DRY
Indoor Conditions
21ºC
25ºC
30ºC
35ºC
40ºC
45ºC
49
ºC
21ºC DB
15ºC WB
Total capacity kW
5.09
5.06
5.03
4.99
4.95
4.91
4.88
Input kW.
1.50
1.51
1.53
1.55
1.60
1.66
1.71
24ºC DB
17ºC WB
Total capacity kW
5.25
5.22
5.18
5.15
5.10
5.06
5.03
Input kW.
1.52
1.53
1.55
1.57
1.63
1.68
1.73
27ºC DB
19ºC WB
Total capacity kW
5.41
5.38
5.34
5.30
5.26
5.22
5.18
Input kW.
1.54
1.55
1.57
1.59
1.65
1.70
1.75
29ºC DB
21
ºC WB
Total capacity kW
5.48
5.44
5.40
5.36
5.32
5.28
5.24
Input kW.
1.56
1.58
1.60
1.62
1.67
1.73
1.78
32ºC DB
23ºC WB
Total capacity kW
5.58
5.55
5.51
5.47
5.42
5.38
5.34
Input kW.
1.57
1.58
1.60
1.62
1.68
1.74
1.79
6.2 CTA-24HVR1
MODEL
CTA-24HVR1
COOLING
OUTDOOR TEMPERATURE DRY
Indoor Conditions
21ºC
25ºC
30ºC
35ºC
40ºC
45ºC
49
ºC
21ºC DB
15ºC
WB
Total capacity kW
6.82
6.78
6.73
6.68
6.63
6.58
6.53
Input kW.
2.03
2.05
2.07
2.10
2.17
2.25
2.31
24ºC DB
17ºC
WB
Total capacity kW
7.04
7.00
6.95
6.89
6.84
6.78
6.74
Input kW.
2.05
2.07
2.10
2.12
2.20
2.28
2.34
27ºC DB
19ºC
WB
Total capacity kW
7.25
7.21
7.15
7.00
7.04
6.99
6.94
Input kW.
2.08
2.10
2.12
2.15
2.23
2.31
2.37
29ºC DB
21
ºC
WB
Total capacity kW
7.34
7.29
7.24
7.19
7.13
7.07
7.03
Input kW.
2.11
2.13
2.16
2.19
2.26
2.34
2.41
32ºC DB
23ºC
WB
Total capacity kW
7.48
7.43
7.38
7.32
7.26
7.21
7.16
Input kW.
2.12
2.14
2.17
2.19
2.27
2.35
2.42
6.3 CTB-36HVR1-A, CTB-36HVR1-B
MODEL
CTB-36HVR1
COOLING
OUTDOOR TEMPERATURE DRY
Indoor Conditions
21ºC
25ºC
30ºC
35ºC
40ºC
45ºC
49
ºC
21ºC DB
15ºC WB
Total capacity kW
10.09
10.03
9.96
9.88
9.80
9.73
9.66
Input kW.
3.08
3.11
3.14
3.18
3.30
3.41
3.51
24ºC DB
17ºC WB
Total capacity kW
10.41
10.35
10.27
10.19
10.11
10.03
9.97
Input kW.
3.12
3.15
3.19
3.22
3.34
3.46
3.55
27ºC DB
19ºC WB
Total capacity kW
10.72
10.66
10.58
10.50
10.42
10.33
10.27
Input kW.
3.16
3.19
3.23
3.27
3.38
3.50
3.60
29ºC DB
21
ºC WB
Total capacity kW
10.85
10.79
10.71
10.63
10.54
10.46
10.39
Input kW.
3.21
3.24
3.28
3.32
3.44
3.56
3.66
Total capacity kW
11.06
10.99
10.91
10.83
10.74
10.66
10.59