![Chigo C2OU-14HVR1 Technical Manual Download Page 16](http://html1.mh-extra.com/html/chigo/c2ou-14hvr1/c2ou-14hvr1_technical-manual_2601238016.webp)
R410A DC Inverter Multi-split Technical Manual
Indoor Units
13
GD Chigo Heating & Ventilation Equipment Co., Ltd.
2.3
107 style indoor units
Model name
CSG-07HVR1(107
)
CSG-09HVR1(107
)
CSG-12HVR1(107
)
CSG-18HVR1(107
)
Power supply
V-ph-Hz
220~240-1-50
220~240-1-50
220~240-1-50
220~240-1-50
Electricity Supplying type
Outdoor unit supply
Cooling
Capacity
Btu/h
7000
9000
12000
18000
Input
W
40
40
40
60
Rated current
A
0.2
0.2
0.2
0.27
Heating
Capacity
Btu/h
8500
10400
13800
19800
Input
W
40
40
40
60
Rated current
A
0.2
0.2
0.2
0.27
Indoor fan
motor
Model
YDK-16-4 3
YDK-16-4 3
YDK-16-4 3
YDK-27-4 A6
Type
PG Motor
PG Motor
PG Motor
Tapping Motor
Brand
CHIGO
CHIGO
CHIGO
CHIGO
Input
W
40
40
40
60
Capacitor
μF
1
1
1
1.8
Speed (H/M/L)
r/min
900/850/800
1000/900/800
1200/1100/1000
1300/1150/1000
Indoor coil
Number of rows
2
2
2
2
Tube pitch * row pitch
mm
21×10.9
21×10.9
21×10.9
21×12.7
Fin spacing
mm
1.5
1.5
1.5
1.6
Fin type
Hydrophilic
aluminum
Hydrophilic
aluminum
Hydrophilic
aluminum
Hydrophilic
aluminum
Tube outside diameter
mm
Ф 5
Ф 5
Ф 5
Ф 7
Tube type
Inner screw
Inner screw
Inner screw
Inner screw
Coil size (W*H*D)
mm
615*121*210
615*121*210
615*121*210
745*138*216
Number of circuits
4
4
4
4
Indoor air flow (H/M/L)
m
3
/h
400/345/290
450/390/327
500/431/364
750/600/420
Indoor noise level (H/M/L)
dB(A)
30/28/26
33/30/27
35/32/28
43/39/35
Indoor unit
Net Dimension (W*H
*D)
mm
800*287*192
800*287*192
800*287*192
900*282*202
Packing Dimension
(W*H*D)
mm
865*358*275
865*358*275
865*358*275
983*377*300
Net/Gross weight
kg
9/11
9/11
9/11
14/16
Refrigerant Type
R410a
R410a
R410a
R410a
Refrigerant pipe (Liquid side/ Gas side)
mm
Ф
6.35/
Ф
9.52
Ф
6.35/
Ф
9.52
Ф
6.35/
Ф
9.52
Ф
6.35/
Ф
12.7
Drainage water pipe diameter
mm
DN25
DN25
DN25
DN25
Controller(standard)
TB-YKQ-D02b
(chigo)
TB-YKQ-D02b
(chigo)
TB-YKQ-D02b
(chigo)
TB-YKQ-D02b
(chigo)
Application area
m
2
13-15
16-20
21-26
32-40
Notes:
1. The cooling conditions: indoor side 27°C(80.6°F) DB, 19°C(60°F)WB outdoor side 35°C(95°F) DB.
2. The heating conditions: indoor side 20°C(68°F) DB, 15°C(44.6°F)WB outdoor side 7°C(42.8°F)DB.
3. Sound level: measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat
higher as a result of ambient conditions.
4. The above data may be changed without notice for future improvement on quality and performance.