background image

PDC Series

Installation Instructions

2

DISCLAIMER

Milestone AV Technologies, Inc., and its affiliated corporations
and subsidiaries (collectively, "Milestone"), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.

 IMPORTANT WARNINGS AND

CAUTIONS!

WARNING:

A WARNING alerts you to the possibility of

serious injury or death if you do not follow the instructions.

CAUTION:

A CAUTION alerts you to the possibility of

damage or destruction of equipment if you do not follow the
corresponding instructions.

WARNING:

Failure to read, thoroughly understand, and

follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty!  It is the
installer’s responsibility to make sure all components are
properly assembled and installed using the instructions
provided.

WARNING:

Failure to provide adequate structural strength

for this component can result in serious personal injury or
damage to equipment!  It is the installer’s responsibility to
make sure the structure to which this component is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component.

WARNING:

Exceeding the weight capacity can result in

serious personal injury or damage to equipment!  It is the
installer’s responsibility to make sure the combined weight of
all components located between the supporting structure and
the PDC does not exceed 400 lbs (181.44 kg) [200 lbs
(90.72 kg) each faceplate].

The weight capacity of the PDC may be LIMITED to the
lowest weight capacity of any other component located
between the PDC and the supporting structure!

2" to 1-1/2" Reducer (NPT Threads)

103

4.06

11.42

290

2.56

65

16.45

418

14.00

356

14.00

356

413

16.27

2.50

64

NOT SHOWN. THE CUSTOM INTERFACE

BRACKET NEEDED FOR YOUR DISPLAY

ALL MEASUREMENTS ARE IN

THE FOLLOWING FORMAT:

[MILLIMETERS]

INCHES

WILL ADD BETWEEN 1/2" AND 2" IN DEPTH

SEE PSBU DRAWING ALSO.

ON THE MOUNT.

AND MAY AFFECT LOCATION OF DISPLAY

NOTE: CUSTOM INTERFACE BRACKET

Product Features

Weight Capacity

400 lbs

200 lbs per faceplate

Roll / Tilt / Yaw

±2.5° / +5°, -25° / 360°

25°

DIMENSIONS

Summary of Contents for PDC Series

Page 1: ...I N S T A L L A T I O N I N S T R U C T I O N S Plasma Dual Ceiling Mount PDC Series ...

Page 2: ... installer s responsibility to make sure all components are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined wei...

Page 3: ... Chave de bocas Chiave a punte aperte Steeksleutel Clé à fourche By Hand A mano Von Hand Com a mão A mano Met de hand À la main Hex Head Wrench Llave de cabeza hexagonal Sechskantschlüssel Chave de cabeça sextavada Chiave esagonale Zeskantsleutel Clé à tête hexagonale Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perfora...

Page 4: ...s Installation Instructions 4 TOOLS REQUIRED FOR INSTALLATION 9 16 14 3 mm PARTS A 1 B 1 1 8 C 1 5 32 D 2 D1 1 D2 1 10 24 D3 1 10 24 x 3 8 D4 1 3 16 D5 1 4 40 x 2 1 2 D6 1 4 40 D7 1 5 16 18 D8 1 5 16 18 x 2 3 4 ...

Page 5: ...xtension and tighten set screw See Figure 2 Figure 2 4 Attach interface brackets to back of displays following instructions included with the interface brackets Installing Displays on PDC WARNING EXCEEDING MAXIMUM WEIGHT CAPACITY CAN LEAD TO SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT It is the installers responsibility to ensure the total amount of weight placed on the mount does not exceed 40...

Page 6: ...ice If so remove nut and pin and move from the lower holes to the upper holes 3 Pull back on flag on upper mounting hole and press pin down down into Open position See Figure 5 Figure 5 WARNING EACH DISPLAY MAY WEIGH IN EXCESS OF 40 LBS EACH Always use two people and proper lifting techniques when installing or positioning displays on PDC 4 Carefully lift displays from PDC 5 Lift up on pin and pla...

Page 7: ...ries 7 Figure 6 Pitch Adjustment 4 Loosen two screws on side of PDC See Figure 6 5 Adjust to desired pitch or vertical movement 6 Tighten the screws on side of PDC x 2 x 2 4 3 2 1 x 2 x 2 5 6 Display and faceplate removed for clarity ...

Page 8: ...401 Eagle Creek Parkway Savage MN 55378 P 800 582 6480 952 894 6280 F 877 894 6918 952 894 6918 Europe A Fellenoord 130 5611 ZB EINDHOVEN The Netherlands P 31 0 40 2668620 F 31 0 40 2668615 Asia Pacific A Room 24F Block D Lily YinDu International Building LuoGang BuJi Town Shenzhen CHINA P 86 755 8996 9226 F 86 755 8996 9217 ...