background image

 PAC502

Installation Instructions

2

DISCLAIMER

Milestone AV Technologies, and its affiliated corporations and 
subsidiaries (collectively, "Milestone"), intend to make this 
manual accurate and complete. However, Milestone makes no 
claim that the information contained herein covers all details, 
conditions or variations, nor does it provide for every possible 
contingency in connection with the installation or use of this 
product. The information contained in this document is subject 
to change without notice or obligation of any kind. Milestone 
makes no representation of warranty, expressed or implied, 
regarding the information contained herein. Milestone assumes 
no responsibility for accuracy, completeness or sufficiency of 
the information contained in this document.

Chief® is a trademark of Milestone AV Technologies. 
All rights reserved.

DEFINITIONS

MOUNTING SYSTEM: 

A MOUNTING SYSTEM is the 

primary Chief product to which an accessory and/or component 

is attached.

ACCESSORY: 

AN ACCESSORY is the secondary Chief 

product which is attached to a primary Chief product, and may 

have a component attached or setting on it.

COMPONENT: 

A COMPONENT is an audiovisual item 

designed to be attached or resting on an accessory or mounting 
system such as a video camera, CPU, screen, display, 
projector, etc.

WARNING:  

A WARNING alerts you to the possibility of 

serious injury or death if you do not follow the instructions.

CAUTION:  

A CAUTION alerts you to the possibility of 

damage or destruction of equipment if you do not follow the 
corresponding instructions.

 IMPORTANT SAFETY INSTRUCTIONS

WARNING:  

Failure to read, thoroughly understand, and 

follow all instructions can result in serious personal injury, 
damage to equipment, or voiding of factory warranty!  It is the 
installer’s responsibility to make sure all accessories are 
properly assembled and installed using the instructions 
provided.

WARNING:  

Failure to provide adequate structural strength 

for this accessory can result in serious personal injury or 
damage to equipment! It is the installer’s responsibility to 
make sure the structure to which this accessory is attached 
can support five times the combined weight of all equipment. 
Reinforce the structure as required before installing the 
accessory. The wall to which the accessory is being attached 
may have a maximum drywall thickness of 5/8” (1.6cm).

 

WARNING:  

Exceeding the weight capacity can result in 

serious personal injury or damage to equipment!  It is the 
installer’s responsibility to make sure the structure to which 
this accessory is attached can support the combined weight 
of the box and all equipment not to exceed 150 lbs (68.0 kg).

NOTES: 

It is the installer’s responsibility to ensure that the 
enclosure is bonded to the ground in the switch box, 
in accordance with the National Electric Code, 
ANSI/NFPA 70 or Canadian Electrical Code, CSA 
C22.1. A green grounding screw is provided in the 
enclosure for the purpose, if required.

The equipment shall be installed and assembled by 
qualified service personnel.

Spacings - To ensure safe operation of the 
equipment installed in the enclosure, per National 
Electric Code ANSI/NFPA 70, a minimum separation 
between power cords and signal or communication 
cables may be required.

This Cabinet System accessory is for use with 
Listed wall mounting systems. Refer to the 
individual mounting system’s installation instructions 
for compatibility.

--SAVE THESE INSTRUCTIONS--

Summary of Contents for PAC502

Page 1: ... O N I N S T R U C T I O N S IN WALL ENCLOSURE Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description PAC502 ...

Page 2: ...ghly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty It is the installer s responsibility to make sure all accessories are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this accessory can result in serious personal injury or damage to equipm...

Page 3: ...W 0 50 13MM TRIM NOT INCLUDED WITH THIS 4 PRODUCT HAS A WIDTH OF 1 INCH DIMENSIONS INCHES MILLIMETERS Tighten Fastener Apretar elemento de fijación Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations Loosen Fastener Aflojar elemento de fijación Befestigungsteil lösen Desapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez...

Page 4: ...x 50mm E 6 08 x 1 2 Extras if needed for installing electrical box F 1 M4 Allen driver bit G 4 2 long 2 short Trim pieces K 16 Tape squares H 4 Cable tie mounts J 12 5 1 2 cable tie L 4 9 16 Grounding screw and washer installed at factory Earthing symbol IEC 60417 No 5019 affixed adjacent to grounding terminal A 1 PAC502 ...

Page 5: ... remove Figure 1 Frame Housing The exposed portion of the center wood stud must be removed and the resulting cavity completely framed with wood The following steps are suggested The actual procedure is dependent upon the specific installation WARNING STRUCTURAL FAILURE HAZARD FAILURE TO TAKE ADEQUATE PRECAUTIONS CAN LEAD TO DEATH OR SERIOUS INJURY Ensure removal of center stud will not cause unacc...

Page 6: ...Allen head connector screws D and mounting spacers B using an M4 Allen head drill bit F See Figure 4 Figure 4 NOTE The PAC502 has 1 2 total clearance between the two studs The spacers allow side to side adjustment 7 Drill eight 3 16 diameter pilot holes in horizontal framing at top and bottom mounting holes See Figure 5 8 Attach the PAC502 A to horizontal framing using eight M7 x 40mm Allen head c...

Page 7: ...vering adhesive back from tape squares K on trim and press trim G against inner wall of box See Figure 7 Figure 7 Installing Mount Assembly 1 Install mount assembly following instructions included with the mount 2 OPTIONAL Cover unused mounting holes in PAC502 with 9 16 caps L Cable Management 1 Attach all cables to display 2 If necessary use cable tie mounts H and cable ties J to secure cables wi...

Page 8: ... com 04 16 USA International A 6436 City West Parkway Eden Prairie MN 55344 P 800 582 6480 952 225 6000 F 877 894 6918 952 894 6918 Europe A Franklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 ...

Reviews: