Installation Instructions
OXCM1U
11
4.
Fasten brackets against ceiling mount extrusion using two
#10-24 x 1/2" socket head cap screws (M). (See Figure 20)
5.
Repeat for other interface bracket.
Figure 20
Adjustments
CAUTION:
Watch for pinch points! Do not place fingers
between movable parts.
Tilt
The interface brackets allow -7.6° to 20° tilt, and can be locked
at -7.6°, -5°, 0°, 5°, 10°, 15° and 20° tilt. (See Figure 21)
Figure 21
1.
If necessary, loosen button head tilt friction bolt (located on
side of interface bracket). (See Figure 22)
2.
Adjust tilt as required. (See Figure 22)
3.
The tilt may be locked at -7.6°, -5°, 0°, 5°, 10°, 15° and 20°
using one 1/4-20 x 2" Phillips head screw (N), one 1/4-20
lock nut (Q) and two 1/4" washers (T) per interface bracket.
(See Figure 21) and (See Figure 22)
NOTE:
Use of washers (T) is optional.
4.
Tighten button head tilt friction bolt as necessary.
Figure 22
4
(M) x 2
(wind shield hidden for clarity)
1.91
48.4
0° HOLE
LOCKOUT
+5°AND -15°
HOLE LOCKOUT
-5° AND -20°
HOLE LOCKOUT
+7.6° HOLE
LOCKOUT
- 10°
2.48
63.0
-10° HOLE
LOCKOUT
Tilt
friction
bolt
1
4
(Displays not shown)
3
(N)
(Q)
0° tilt
20° tilt
2
(T) x 2