Model: MSP-WTIKTA220
Installation Instructions
6
Figure 10: Install End Lock(s)
ADJUSTMENTS
Array Adjustment
The WTIKTA220 allows for both vertical and horizontal
position adjustment on pole.
To adjust position:
1.
Loosen single (right) rear adjustment screw.
(See Figure 11)
2.
Move array to desired position. (See Figure 11)
3.
Tighten adjustment screw.
ALWAYS use two people when adjusting FSA-1017
position.
Figure 11: Pole Mount Adjustment
Display Adjustment
The WTIKTA220 allows horizontal, pitch, roll, and yaw
adjustment of each display with a maximum pitch range
of 15° up and 15° down.
The WTIKTA220 also allows a full 360 deg. of display
roll.
Display Horizontal Position Adjustment
To adjust display horizontal position:
1.
Loosen Centris bracket rear adjustment knob.
(See Figure 12)
2.
Slide Centris bracket with display left or right until
properly positioned on array rail.
3.
Tighten Centris bracket rear adjustmnent knob.
Figure 12: Display Horizontal Adjustment
Display Pitch, Roll, and Yaw Adjustment
To adjust display position:
1.
Loosen Centris bracket front adjustment knob.
(See Figure 13)
2.
Tilt display up or down, or adjust display roll left or
right until properly positioned.
3.
Tighten Centris bracket front adjustmnent knob.
Figure 13: Display Pitch and Roll Adjustment
End Lock
End Lock Retaining Screw
Centris Head
Array Rail
View From Rear
Adjustment Screw