background image

CONTROLLER BOARD BOX

TERMINAL FUNCTION DEFINITIONS

TERMINAL

NUMBER

FUNCTION

DESCRIPTION

WIRING OPTIONS

NOTES

1

24 VOLT AC

24 volt AC output

2

24 VOLT AC

COMMON

24 volt AC common

This is an internal power
supply for powering external
devices & Remote
Controllers.

Chief Mfg. offers the RC-10
Radio Frequency Remote
Controller which runs off of
this power supply.

3

GROUND

Ground

4

12 VOLT DC

12 volt DC

This is an internal power
supply for powering external
devices &/or used for
initiating specific functions
(Extend/Retract 5 or Voltage
Sensor 7).

5

EXTEND/

RETRACT

Initiates movement if lift is static, or

stops movement if lift is in motion.

Direction of travel will be opposite of

last direction of travel.

Function operates on
momentary switch only.

Operating range is 5 – 30
Volts AC or DC.

6

EXTEND/

RETRACT

COMMON

Used in conjunction with

Extend/Retract when using an

external power source to initiate

movement.

To Operate using Internal Power
Source
Connect terminals 3 & 6 with
Jumper Wire.  Connect Momentary
Switch to terminal 4.  Connect
other line of Momentary Switch to
terminal 5.

To Operate using External Power
Source
Connect External Power Supply’s
Common to terminal 6.  Connect
initiating signal to terminal 5.

NOT TO BE USED AS
GROUND FOR FUNCTION
OTHER THAN
EXTEND/RETRACT
TERMINAL 5.

7

VOLTAGE

SENSOR

When terminal senses voltage, unit

will extend.

When terminal senses cessation of

voltage, unit will retract.

Operating range is 5 – 30
Volts AC or DC.

8

VOLTAGE

SENSOR

COMMON

Used in conjunction with Voltage

Sensor when using an external power

source to initiate movement.

Voltage Sensing
Connect positive lead to terminal 7.
Connect Ground of switching
device to terminal 8.

Single-Pull/Throw Latching Switch
Connect terminals 3 & 8 with
Jumper Wire.  Connect first Switch
Terminal to terminal 4.
Connect other Switch Terminal to
terminal 7.

NOT TO BE USED AS
GROUND FOR FUNCTION
OTHER THAN VOLTAGE
SENSOR TERMINAL 7.

9

SERVICE

EXTEND

Extends unit to maximum limit,

bypassing normal-use travel setting.

Often used for servicing projectors in

ceiling lifts.

Momentary or Latching contact to
Ground terminals 3, 10, 13, or 20.

Feature not available on all
models.

If using Latching Switch, be
sure to disengage Switch prior
to initiating any other
function.

10

GROUND

Ground

Reviews: