Installation Instructions
FCA4U / LCM4U
7
1.
Slide quad ceiling accessory (A) up from below onto
installed column (not included). (See Figure 3)
2.
Tighten two existing 5/16 x 1-1/2" button head cap screws
in center of quad ceiling accessory. (See Figure 3)
3.
Slide bottom stop collar onto installed column, lining up
holes in collar with holes in column.
Figure 3
4.
Install two 5/16" x 1" self-tapping screws through two 5/16"
flat washers, bottom stop collar, and into installed column.
5.
Install and tighten 5/16" x 3/4" set screw into bottom stop
collar. (See Figure 3)
6.
Loosen two button head screws tightened in Step 2, and
slide accessory down extension column until it rests on the
bottom stop collar. (See Figure 3)
7.
Tighten two button head cap screws (loosened in Step 6) in
center of quad ceiling accessory. (See Figure 3)
Installing Mount Assemblies and Screens
NOTE:
In the following Steps 1-6, parts
not
designated with a
letter are included with mount assemblies.
1.
OPTIONAL:
Slide one rotation ring (D) up onto leg of the
quad ceiling accessory (A). (See Figure 4)
NOTE:
The rotation rings only need to be installed if the mount
assemblies will be rotated after installation.
2.
Slide mount assembly onto leg of the quad ceiling
accessory.
3.
Insert one rotation ring (D) below mount assembly on leg of
the quad ceiling accessory. (See Figure 5)
4.
Thread bottom coupling onto leg of quad ceiling accessory
until tight, with a minimum of four threads engaged. (See
Figure 5)
5.
Install and tighten one 10-24 x 1/4" set screw into bottom
coupling. (See Figure 5)
Figure 4
Figure 5
6.
Install and tighten two 5/16" nylon tipped set screws (E) [
OR
two 5/16" set screws included with mount assembly]
through back of mount assembly and against column. (See
Figure 5)
NOTE:
The nylon tipped set screws (E) only need to be
installed if the mount assemblies will be rotated after
installation. If no rotation is necessary, use 5/16" set
screws from mount assemblies hardware.
7.
Repeat Steps 1 through 6 for remaining mount assemblies.
8.
Complete installation
following the remaining steps in
the Installation Instructions included with the mount
assemblies
.
Cable Management
1.
Cables may be routed through columns and arms of
FCA3U.
2.
Use cable zip clips (F) and cable ties (G) as required to hold
cables in place.
1
(A)
3
4
5
2
7
6
(D)
(A)
1
(D)
2
4
bottom
coupling
5
10-24 x 1/4"
6
(E) x 2