INSTALLATION
Mount Installation
IMPORTANT ! :
The following installation instructions
assume that a 1-1/2" NPT pipe has been properly
installed and is in place.
1.
Assemble the CMA-365 (T) and CMA-048 (U) together
following instructions included with those kits.
2.
Thread assembled CMA-365 (T) with CMA-048 (U) onto
1-1/2" NPT pipe until hand tight. (See Figure 1)
3.
Slide two mounts (A) onto CMA-048 (U) column, one on
each side of the CMA-365 (T).
Figure 1
4.
When mount (A) is properly positioned secure mount (A) to
CMA-048 column (U) by installing and tightening two
5/16-18 x 3/8" set screws (B) into each mount (A) using
3/16" hex wrench (P). (See Figure 2)
Figure 2
5.
Place vinyl end caps (S) on each end of column (U).
(See Figure 2)
Display Installation
1.
Determine mounting pattern on display.
WARNING:
IMPROPER INSTALLATION CAN LEAD TO
EQUIPMENT FALLING CAUSING SERIOUS PERSONAL
INJURY AND DAMAGE TO EQUIPMENT! DO NOT
substitute hardware. Use only hardware supplied by
manufacturer!
WARNING:
IMPROPER INSTALLATION CAN LEAD TO
ELECTRIC SHOCK OR DAMAGE TO EQUIPMENT! Screw
length must not exceed the depth of threaded mounting insert
in display.
WARNING:
OVERTIGHTENING OF SCREWS CAN
DAMAGE PARTS AND LEAD TO SERIOUS PERSONAL
INJURY AND DAMAGE TO EQUPIMENT! DO NOT over
tighten screws when installing interface bracket.
NOTE:
If the display being installed has a 100x100 VESA
mounting pattern, no interface bracket is required and
the display can be mounted directly to the Centris cup.
Attach VESA Bracket to Display
1.
Lay display face down on a clean and dry flat surface.
2.
Attach VESA Plate (R) to display using appropriate screws
(D, E, F, G, H, L, M, N). (See Figure 3)
NOTE:
If the display has a recessed mounting surface,
spacers (K or O) between the display and VESA plate
(R) may be required.
3.
Tighten all screws.
Figure 3
2
1-1/2" NPT Pipe
(T)
(U)
4
(B) x 4
(A)
(U)
5
(S) x 2
(D, E, F, G, H, L, M, N) x 4
2