background image

INSTALLATION GUIDE 

Connex

Sys  

series

™ 

CURVED VIDEO WALL GUIDELINES

The ConnexSys™ LVSXU is UL listed for use in certain curved video wall applications – but how do you know 

if your install fits the criteria? Use this guide to determine if ConnexSys is a good match for your curved wall 

installation. For comprehensive guidelines on mounting the LVSXU please reference the installation manual.

Strut Channel & Curve Radius Requirements

ConnexSys is compatible with curved walls built in a radius of 200

"

 (5.08 m) or greater. The strut channel 

material being used should also follow the guidelines listed in the chart below

Calculating the Wall Radius

1.     Place a rigid, flat stick or strut channel (at least 3 ft or 1 m long – preferably longer) against the curved  

       wall as shown in the example below. Do NOT bend the stick or strut.

2.  Measure the largest gap between the stick or strut and the wall.

3.  Calculate the radius with the following equation: 

 

Gap/2 + (Length/8 x Length/Gap) = Radius

 

Example

 

 

Stick/Strut Length: 48” (121.9 cm) 

 

Gap: 0.375” (9.5 mm) 

 

0.375/2 + (48/8 x 48/0.375) = 768” (19.5 m) Radius

STRUT CHANNEL MATERIAL

Aluminum

Steel

Minimum Wall Radius

Greater than 200

"

 (5.08 m)

Greater than 400

"

 (10.16 m)

Minimum Yield Strength

30 ksi (207 MPa)

33 ksi (230 MPa)

Material Thickness

0.078” (2 mm)

14 ga – 0.075

"

 (2 mm) or 12 ga – 0.104

"

 (2.5 mm)

Strut Channel Depth

13/16

"

 (21 mm) or 7/8

"

 (22 mm)

Flange Length

1/4 - 9/32

"

 (6-7 mm)

Curved Wall

Flat Stick or Strut

(view from above - image is exaggerated)

Gap

Reviews: