background image

Installation Instructions

CMA-440 Light Weight Suspended Ceiling Kit

4

ASSEMBLY PROCEDURES

Hang Ceiling Tray

WARNING:  Improper installation can cause serious per-
sonal injury!  Make sure that the ceiling structural mem-
bers can support a redundant weight factor

five times

 the

total weight of the equipment you intend to support over-
head.  The ceiling must be reinforced before you install the
Kit if the ceiling cannot support a redundant weight factor

five times

 the total weight of the equipment.

1. Insert the center bolt bracket from the under-side of the ceiling

tray (see Figure 1).

2. Secure the ceiling mount bracket to the center bolt bracket

using four wing nuts and washers provided.

3. Remove the tiles from the area where mounting the ceiling

tray.

4. Place the ceiling tray in its mounting location and mark the

mounting hole where the pipe will protrude from the ceiling.

5. Install the ceiling tile and ceiling tray and clamp the ceiling

tray to the ceiling track.

6. If necessary, remove outlet box knockout(s) from ceiling tray

and install electrical outlet box(es) in the opening(s).

7. Place the ceiling tray into the 24 x 24 in. (600 x 600 mm) or

24 x 48 in. (600 x 1200 mm) opening in the ceiling in place of
a ceiling tile, or mount the tray above the ceiling (see
Figure 2 for SAE applications or see Figure 3 for metric appli-
cations).

8. Using four 10 x 24 x 5/8” Phillips-head self-tapping screws in

the inside four holes for SAE applications (see Figure 2) or in
the outside four holes for metric applications (see Figure 3) of
the ceiling tray, clamp the ceiling tray to the ceiling runners.

9. Hook turnbuckles into the hanger brackets.

Secure to grid

Hook turnbuckles

Figure 2.  Bracket Attachment for USA/SAE

Figure 1.  Center Bolt Ring Attachment

Figure 3.  Bracket Attachment for Europe/Metric

Hook turnbuckles

Secure to grid