4.

Press and release the Activator Button on the front of the
Motor Box or the "Close Door button on the Remote Control.
(The doors should travel to the fully closed position)

Figure 6

5.

Press the "Open Door" button on the Remote Control.

ADJUSTMENTS

Adjust Door Travel Distance

To adjust door travel distance:

1.

Press and hold the activator button on the front of the motor
box for 13 seconds.

The Status Light on the front of the motor box will begin to blink
alternately red and green. When this starts to happen release
the Activator Button. When put into "Learn Moden the system
runs back and forth several times and measures it's
environment, such as open and closed locations etc. The
system will then stop and remember these learned
measurements.

Figure 7

System Controls and Indicators

Learn Mode

The CM6SV system has no limit switches. The system uses an
encoder on the motor to collect data and send it to the micro
processor’s memory. The software "learns" about its
environment (speed, time duration, stop points, etc.) during the
initial setup of the unit and retains that information until
requested to "relearn" its environment.

The unit is shipped pre-set from the factory and will then
continually adjusts to it’s enviornment on each activation.

If for some reason you want to place the system into “Learn
Mode” (such as to stop at other than its normal stop points),
Press and hold the red activator button on the front of the motor
box for approxamatly 13 seconds and then release it when the
Status Light flashes quickly red, green, red, green, red, green.

Figure 8

The controller will then be in “Learn Mode” (The door will move
for 3 seconds, stop for 10 seconds, and when it starts moving
again it will be in it’s “Learn Mode”).

When put into “Learn Mode” the mechanism runs back and
forth several times and measures it’s environment, such as
open and closed locations etc., and then stops and remembers
these learned measurements, so that next time the system runs
it knows where to start and stop.

Status Light Codes

There is a light on the front of the mechanism motor box that
will tell through its pattern of flashes and colors what the
mechanism is doing.

Figure 9

Normal Doors At Rest -

The Status Light will be on steady

green.

Normal Run Motion of Doors

- The Status Light will flash in

groups of 2 green followed  by  a pause. In normal run motion
the doors on the system have a variable speed. The  doors will
start slowly, accelerate to a fast speed, and then slow down
before coming to a stop.

Doors Obstructed

- The Status Light will flash in groups of 3

red followed by a pause. If  the doors meet an obstruction they
will sense the obstruction, stop momentarily, and move in  the
opposite direction for a few seconds. ---- Remove the
obstruction and then activate the doors. They should return to
normal run motion.

Doors Obstructed Both Ways

- The Status Light will flash in

groups of 4 red followed by  a  pause. Similar to Doors
Obstructed but doors are prevented from moving in either
direction. ----  Remove the obstruction and then activate the
doors. They should return to normal run motion.

Travel Too Far

- The Status Light will flash in groups of 5 red

followed by a pause. The  motor  is running but the doors are
not moving. ---- Has the motor box been uncoupled from the
track,  or is the motor box bent, causing it to become uncoupled
from the track?

Power Loss

- The Status Light will be on solid red. ---- There

has been a power loss (due  to  an electrical storm, etc.). When

Activator

Activator

Activator Button

Status Indicator

Summary of Contents for CM6DV SERIES

Page 1: ...e protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio or television communications However there is no guarantee that the interference will not occur in a particular installation If this equipment does cause...

Page 2: ...er s responsibility to make sure all components are properly assembled and installed using the instructions provided Read all instructions before using this furnishing DANGER TO REDUCE THE RISK OF ELECTRIC SHOCK ALWAYS unplug this furnishing from the electrical outlet before cleaning WARNING TO REDUCE THE RISK OF BURNS FIRE ELECTRIC SHOCK OR INJURY TO PERSONS Unplug from outlet before putting on o...

Page 3: ...he motion of the doors the doors stop reverse run a few seconds and then stop again Auxiliary Controls There is an activator button located on the front of the motor box which will activate the doors Status Light The Status Light on the front of the Motor Box indicates the operating condition of the mechanism In normal operating conditions the status light will be solid green with the doors at res...

Page 4: ... Wheel Plates on the left and right tracks are tight to the track They may have come loose during shipment If they are not tight loosen the red shipping screw in the center of the plate While firmly pushing on the outside of the Wheel Plate re tighten the red shipping screw It is important that the all Wheel Plates fit tightly to the tracks before proceeding 5 To attach the top door to the mechani...

Page 5: ...Installation Instructions CM6DV SERIES 5 Figure 2 ...

Page 6: ...CM6DV SERIES Installation Instructions 6 Figure 3 ...

Page 7: ... that it gives the sensor line of sight to the signal from the remote controller Often this merely involves placing the IR sensor so that it peeks up over the top of the cabinet It doesn t have to be much just enough to give line of sight Two an IR sensor extension cord can be used to position the IR sensor in the cabinet near to the other remote controlled units For example near to the VCR or DVD...

Page 8: ...for 3 seconds stop for 10 seconds and when it starts moving again it will be in it s Learn Mode When put into Learn Mode the mechanism runs back and forth several times and measures it s environment such as open and closed locations etc and then stops and remembers these learned measurements so that next time the system runs it knows where to start and stop Status Light Codes There is a light on t...

Page 9: ... 8 Open Position 7 Stop IR Receiver Eye input for Eubank Inc supplied external IR reciever only Position 6 V out Position 5 Vcc 5v Radio Power for external RF reciever only Position 4 24 VDC Sequence control for use with 3rd party control Position 3 Sequence Open Stop Close Stop Position 2 Common Discrete control for use with 3rd party control Position 1 Close Control Input on Front of Motor Box F...

Page 10: ...8 952 894 6918 Europe A Fellenoord 130 5611 ZB EINDHOVEN The Netherlands P 31 0 40 2668620 F 31 0 40 2668615 Asia Pacific A Room 30I Block D Lily YinDu International Building LuoGang BuJi Town Shenzhen CHINA Post Code 518112 P 86 755 8996 9226 8996 9236 8996 9220 F 86 755 8996 9217 8820 000020 2007 Chief Manufacturing www chiefmfg com 03 07 ...

Reviews: